Remote control commands
R&S
®
RTM3000
717
User Manual 1335.9090.02 ─ 09
17.12.3
Report
............................................................................................717
.......................................................................................... 717
POWer:REPort:ADD
Adds a power report.
Usage:
Event
POWer:REPort:DESCription
Sets a description that can be shown at the titel page of a report.
Parameters:
<DescriptionString>
String parameter
POWer:REPort:DUT
Sets a device under test (DUT) value that can be shown at the titel page of a report.
Parameters:
<DeviceString>
String parameter
POWer:REPort:OUTPut
Sets the directory for the output folder, where the reports are stored.
Parameters:
<OutputFolderPath> String parameter
POWer:REPort:SITE
Sets a site value that can be shown at the titel page of a report.
Parameters:
<SiteString>
String parameter
POWer:REPort:TEMPerature
<Temperature>
Sets a temperature value that can be shown at the titel page of a report.
Power analysis (option R&S
RTM-K31)