1.

 

I

NTRODUCTION

 

This  manual  contains  minimum  information  that  is  necessary  to  properly  install  and  configure 
RFT1000 readers in RACS 5 access control system. Additional information on RACS 5 configuration 

can  be  found  in  the  Application  Note  AN006  RAC  5  Quick  Start  Guide  which  is  available  at 

www.roger.pl

The application of RFT1000 reader in RACS 4 and third party systems is described in 

dedicated documents which are also available at 

www.roger.pl

. 

2.

 

D

ESCRIPTION AND 

S

PECIFICATION

 

RFT1000 biometric reader operates as access control terminal and/or Time&Attendance terminal in 

RACS  5  system.  RFT1000  is  equipped  with  fingerprint  scanner  and  Mifare  Ultraligth/Classic/Plus/ 
DESFire  proximity  card  reader.  Users  can  be  identified  by  comparison  of  their  fingerprints  with 

fingerprint  templates  recorded  in  reader’s  memory  (1:N  mode)  or  by  comparison  of  their 
fingerprints with fingerprint templates recorded in  Mifare card memory (1:1 mode). The reader is 
not  a  standalone  device  and  it  must  be  connected  to  MC16  controller.  The  communication  in 
LAN/WAN is encrypted with AES128 CBC method. 
 

 

Fig. 1 The example of RFT1000 operation with MC16-PAC-1-KIT  

Table 1. Specification 

Maximum 

number 

of 

fingerprint templates 

1900 

Fingerprint 

identification 

modes 

1:N mode – fingerprint templates are recorded in reader memory 
1:1 mode – fingerprint templates are recorded on Mifare cards 

Содержание RFT1000

Страница 1: ...on 1 3 or newer Hardware version 1 1 Document version Rev A 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the www roger pl website of the Roger sp z o o sp k company hereinafter referred to as ROGER ...

Страница 2: ...3 6 Use installation guidelines 6 4 Configuration 7 4 1 Low level configuration RogerVDM 7 4 1 1 Configuration of communication parameters 7 4 1 2 Recognition modes 8 4 1 4 Inputs 9 4 2 Communication with RFT1000 VISO 10 4 3 User enrolment in 1 N mode 10 4 4 User enrolment in 1 1 mode 10 4 4 1 Master Authorisation 11 4 5 User identification 11 4 6 Full memory reset 12 4 7 Firmware update 12 5 Orde...

Страница 3: ...e Attendance terminal in RACS 5 system RFT1000 is equipped with fingerprint scanner and Mifare Ultraligth Classic Plus DESFire proximity card reader Users can be identified by comparison of their fingerprints with fingerprint templates recorded in reader s memory 1 N mode or by comparison of their fingerprints with fingerprint templates recorded in Mifare card memory 1 1 mode The reader is not a s...

Страница 4: ...ntact NC type 24V 50 mA rated Environmental class according to EN 50131 1 Class I indoor general conditions temperature 5 C to 40 C relative humidity 10 to 95 no condensation IP code IP41 Dimensions H x W x D 85mm x 85mm x 52mm Weight 160g Certificates CE 3 INSTALLATION 3 1 Terminals and connection diagram Fig 2 RFT1000 terminals Table 2 RFT1000 terminals Terminal Description 12V Positive power su...

Страница 5: ... indicators on its enclosure which function according to table 3 Table 3 LED indicators Symbol Name Colour Description STATUS Red Green Armed Disarmed mode of reader OPEN Green Door unlocked SYSTEM Orange Various signalling functions e g microcontroller memory failure configuration errors etc 3 3 Power supply RFT1000 reader requires 12 VDC supply voltage The supply must be connected to 12V termina...

Страница 6: ...protector from fingerprint scanner Otherwise it may hinder fingerprint scanning In case of connection through Ethernet port twisted pair cable should be uninsulated in the shortest possible distance and wires should remain twisted in the longest possible distance It is required to install proximity card readers in minimal distance of 0 5m from each other In order to ensure correct operation of the...

Страница 7: ...with default empty password Connection and configuration procedure 1 Connect the reader to computer by means of Ethernet port 2 Configure your computer s network parameters according to RFT1000 default settings The IP address of the computer must be in the same subnet i e 192 168 0 xxx 3 Install and start RogerVDM software 4 In the opened window fig 6 select RFT1000 v1 0 device firmware 1 3 and Et...

Страница 8: ...eld assign unoccupied address to RFT1000 on RS485 bus of MC16 access controller in range of 100 115 10 Upload settings to the reader with Send to Device button 4 1 2 Recognition modes In case of RFT1000 it is necessary to select one of following recognition modes 1 N mode templates in reader s memory in this mode fingerprint templates are recorded in memory database of RFT1000 reader Users are ide...

Страница 9: ...nu of RogerVDM software fig 7 When RFT1000 reader is installed in RACS 5 system only the function 5 Card Reader Mode is applicable Other available functions are used beyond RACS systems In general input functions of Roger devices depending on assigned functions can be momentary or constant type Therefore device may detect only activation of input momentary type or activation and deactivation of in...

Страница 10: ... Readers icon 2 In the opened window select Add button and enter communication parameters which were previously configured with RogerVDM including IP address port and communication password 3 Verify settings with Test connection button 4 3 User enrolment in 1 N mode In 1 N mode user enrolment including fingerprint scanning and assignment of access rights is done in VISO software It is recommended ...

Страница 11: ... store 1 fingerprint template while Mifare Classic 4k card can store up to 7 fingerprint templates Mifare Ultralight cards do not have enough memory to store any fingerprint template 4 5 User identification User identification by RFT1000 reader depends on selected recognition mode section 4 2 1 input with function 5 Card Reader Mode section 4 1 4 and the option Card reader mode fig 7 Input 5 is us...

Страница 12: ...ncluding users data base and restores factory default settings Reset procedure 1 Switch off power supply to RFT1000 2 Remove connections to CLK and IN2 terminals 3 Connect CLK terminal with IN2 terminal 4 Switch on power supply to RFT1000 The reader shall generate continuous acoustic signal 5 Disconnect CLK and IN2 terminals Communication parameters after reset IP address 192 168 0 70 Subnet mask ...

Страница 13: ...uct or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and ...

Отзывы: