In  order  to  ensure  this,  all  GND  terminals  of  various  power  supply  units  in  the  system  must  be 

connected with each other using separate wire. Alternatively, the common negative pole (GND) of 
the entire system can be earthed, but only in single point. 

3.4 Inputs 

RFT1000  reader  is  equipped  with  two  (IN1,  IN2)  inputs  which  can  be  configured  as  NO/NC  with 

RogerVDM  software.  Inputs  can  be  assigned  with  functions  using  RogerVDM  software  and  VISO 
software where they are operated in the same way as any other inputs of controller or peripheral 
devices. The configuration and application of inputs is optional. 

3.5 Wall mounting 

 

Fig. 4 RFT1000 installation 

3.6 Use/installation guidelines 

 

All electric cables must be connected to devices with disconnected power supply. 

 

If the range of card reading is significantly lower than specified in technical documentation then 
consider relocation of reader. 

 

After  installation  of  RFT1000  reader,  remove  protector  from  fingerprint  scanner.  Otherwise  it 
may hinder fingerprint scanning. 

 

In  case  of  connection  through  Ethernet  port,  twisted  pair  cable  should  be  uninsulated  in  the 
shortest possible distance and wires should remain twisted in the longest possible distance. 

 

It is required to install proximity card readers in minimal distance of 0.5m from each other.  

 

In order  to ensure correct operation of the reader  it is necessary to clean fingerprint scanner 
regularly  by  means  of  wet  cloth  and  mild  detergent.  Do  not  clean  by  means  of  abrasive 
materials  and  strong  cleaners  like  alcohols,  solvents,  etc.  Damages  to  scanner  surface  are 
beyond the scope of warranty. 

 

RFT1000 reader should be installed in shaded and dry place, far from heat and moisture. It is 
necessary  to  avoid  dust  and  abrupt  temperature  changes.  The  reader  cannot  be  installed  in 
places exposed to direct sunlight. In the event of exposure of the device to direct sunlight or 

strong artificial light it may operate improperly. 

 

Proper finger placing  for the purpose of fingerprint reading is shown in fig. 5. In case of kids 
(small  fingerprints)  it  is  recommended  to  verify  fingerprint  reading  prior  to  installation  of 
RFT1000. 

Содержание RFT1000

Страница 1: ...on 1 3 or newer Hardware version 1 1 Document version Rev A 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the www roger pl website of the Roger sp z o o sp k company hereinafter referred to as ROGER ...

Страница 2: ...3 6 Use installation guidelines 6 4 Configuration 7 4 1 Low level configuration RogerVDM 7 4 1 1 Configuration of communication parameters 7 4 1 2 Recognition modes 8 4 1 4 Inputs 9 4 2 Communication with RFT1000 VISO 10 4 3 User enrolment in 1 N mode 10 4 4 User enrolment in 1 1 mode 10 4 4 1 Master Authorisation 11 4 5 User identification 11 4 6 Full memory reset 12 4 7 Firmware update 12 5 Orde...

Страница 3: ...e Attendance terminal in RACS 5 system RFT1000 is equipped with fingerprint scanner and Mifare Ultraligth Classic Plus DESFire proximity card reader Users can be identified by comparison of their fingerprints with fingerprint templates recorded in reader s memory 1 N mode or by comparison of their fingerprints with fingerprint templates recorded in Mifare card memory 1 1 mode The reader is not a s...

Страница 4: ...ntact NC type 24V 50 mA rated Environmental class according to EN 50131 1 Class I indoor general conditions temperature 5 C to 40 C relative humidity 10 to 95 no condensation IP code IP41 Dimensions H x W x D 85mm x 85mm x 52mm Weight 160g Certificates CE 3 INSTALLATION 3 1 Terminals and connection diagram Fig 2 RFT1000 terminals Table 2 RFT1000 terminals Terminal Description 12V Positive power su...

Страница 5: ... indicators on its enclosure which function according to table 3 Table 3 LED indicators Symbol Name Colour Description STATUS Red Green Armed Disarmed mode of reader OPEN Green Door unlocked SYSTEM Orange Various signalling functions e g microcontroller memory failure configuration errors etc 3 3 Power supply RFT1000 reader requires 12 VDC supply voltage The supply must be connected to 12V termina...

Страница 6: ...protector from fingerprint scanner Otherwise it may hinder fingerprint scanning In case of connection through Ethernet port twisted pair cable should be uninsulated in the shortest possible distance and wires should remain twisted in the longest possible distance It is required to install proximity card readers in minimal distance of 0 5m from each other In order to ensure correct operation of the...

Страница 7: ...with default empty password Connection and configuration procedure 1 Connect the reader to computer by means of Ethernet port 2 Configure your computer s network parameters according to RFT1000 default settings The IP address of the computer must be in the same subnet i e 192 168 0 xxx 3 Install and start RogerVDM software 4 In the opened window fig 6 select RFT1000 v1 0 device firmware 1 3 and Et...

Страница 8: ...eld assign unoccupied address to RFT1000 on RS485 bus of MC16 access controller in range of 100 115 10 Upload settings to the reader with Send to Device button 4 1 2 Recognition modes In case of RFT1000 it is necessary to select one of following recognition modes 1 N mode templates in reader s memory in this mode fingerprint templates are recorded in memory database of RFT1000 reader Users are ide...

Страница 9: ...nu of RogerVDM software fig 7 When RFT1000 reader is installed in RACS 5 system only the function 5 Card Reader Mode is applicable Other available functions are used beyond RACS systems In general input functions of Roger devices depending on assigned functions can be momentary or constant type Therefore device may detect only activation of input momentary type or activation and deactivation of in...

Страница 10: ... Readers icon 2 In the opened window select Add button and enter communication parameters which were previously configured with RogerVDM including IP address port and communication password 3 Verify settings with Test connection button 4 3 User enrolment in 1 N mode In 1 N mode user enrolment including fingerprint scanning and assignment of access rights is done in VISO software It is recommended ...

Страница 11: ... store 1 fingerprint template while Mifare Classic 4k card can store up to 7 fingerprint templates Mifare Ultralight cards do not have enough memory to store any fingerprint template 4 5 User identification User identification by RFT1000 reader depends on selected recognition mode section 4 2 1 input with function 5 Card Reader Mode section 4 1 4 and the option Card reader mode fig 7 Input 5 is us...

Страница 12: ...ncluding users data base and restores factory default settings Reset procedure 1 Switch off power supply to RFT1000 2 Remove connections to CLK and IN2 terminals 3 Connect CLK terminal with IN2 terminal 4 Switch on power supply to RFT1000 The reader shall generate continuous acoustic signal 5 Disconnect CLK and IN2 terminals Communication parameters after reset IP address 192 168 0 70 Subnet mask ...

Страница 13: ...uct or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and ...

Отзывы: