Note: If you observe that after selection of a reader’s operation mode or after
power up of a unit, the LED SYSTEM is on and accompanied with acoustic signal
it means that the contents of reader’s memory is corrupted or the
MASTER/INSTALLER card are not programmed. In this case you must perform the
full
Memory Reset
and completely re-program a reader.
Example: Configuring the PRT12 reader for Online Wiegand 66 bit interface
Power down the unit
Remove all connections from DTA and IN1 lines.
Connect DTA to IN1
Restore power, the reader generates a continuous beep
Wait until the LED SYSTEM starts flashing
Disconnect DTA from IN1
Press [7]
Wait for the prompt signal (two short beeps)
Press [0]
Once the previous step is completed the reader is configured for Wiegand 66 bit
operation mode
7.4.
Memory Reset - programming MASTER and INSTALLER
users
The
Memory Reset
erases all cards and PINs including card/PIN for MASTER and
INSTALLER. Also, it causes the reader restores the factory-shipped default settings.
The
Memory Reset
has practical sense for
Offline
modes only, it does not affect the
unit if it is configured for
Online
mode.
To perform Memory Reset follow these steps:
Power down the unit
Remove all connections from CLK and IN1 lines
Connect CLK to IN1
Restore power, the reader will generate a continuous signal
Wait until the LED OPEN starts flashing
Disconnect CLK from IN1
Enter PIN code for MASTER (e.g. 1111#) or skip this step and go to the next
one
Present any card to the reader, this card becomes a new MASTER card or if you
don’t want to program MASTER card, press [#] – reader will skip this
programming step and will jump to the next one
Enter PIN code for INSTALLER (e.g. 2222#) or skip this step and jump to the
next one
Present any card to the reader, this card becomes a new INSTALLER card or if
you don’t want to program INSTALLER card, press [#] – reader will skip this
programming step and will jump to next one
Once the previous step has been completed reader automatically ends the
Memory Reset
and enters the
Armed
mode
Note: For MASTER and INSTALLER you may program PIN, card or both of them (i.e.
PIN and card). Only one form of identification (card or PIN) is required to enter
Содержание PRT12 v1.3
Страница 1: ...PRT12 v1 3 RFID PIN Outdoor Access Terminal Firmware v75 6 Installation and Programming Guide ...
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ... This page intentionally left blank ...
Страница 36: ......
Страница 39: ...Notes No Fault description filled out by the customer Date of repair filled out by the service 1 2 3 4 5 ...