PRT12 v1.3 fv75.6 EN Rev.D.doc
10/22/2007
_________________________________________________________________________________________
Page 16 of 40
7x
Online
mode,
66 bit
Wiegand
communication
interface
Note: For
Wiegand
data formats the second digit of a code (marked as X) specifies the method which reader
employs when transmitting PIN codes. For details regarding methods of PIN transmission refer to table below.
PIN Transmission Options
X Code
Description
Details
X=0
1-10 digits long PIN,
transmitted in BCD
format
Each key pressed is buffered in reader’s memory, with a press of a
[#] key reader transmits entire PIN code. The PIN code is transmitted
as a BCD coded number.
X=1
1-12 digits PIN,
transmitted in binary
format
Each key pressed is buffered in reader’s memory, with a press of a
[#] key reader transmits entire PIN code. The PIN code is transmitted
as a binary number.
X=2
Each key pressed is
transmitted separately
with two control bits
Each key pressed is immediately transmitted to the host controller as
a sequence of 6 bits (EXXXXP) where XXXX represents the code of
the pressed key supplemented by two control bits (E and P). The E
represents the even bit calculated from the first half of a transmitted
code where P represents the parity of a second half of the bit stream.
This format is compatible with HID 5355 series readers, option:
With
Parity
.
X=3
Each key pressed is
transmitted separately,
no control bits added
Each key pressed is immediately transmitted to the host controller as
a sequence of 4 bits (XXXX) which represent the code of the pressed
key, no control bits added. This format is compatible with HID 5355
series readers, option:
Without Parity
.
Note: The PIN code transmission options described in this table apply to 26/34/42/66bit Wiegand data formats
only.
When the reader is set for
Stand-alone
mode (
Offline
), installer must program to a
reader two special cards: MASTER and INSTALLER and then enter the
Installer
Programming
mode in order to make final configuration settings. The programming
of the cards and PINs can be carried out in the
User Programming
mode.
To configure PRT12 operating mode follow these steps:
Power down the unit
Remove all connections from DTA and IN1 lines
Connect DTA to IN1
Restore power, the reader generates a continuous beep
Wait until LED SYSTEM starts flashing
Disconnect DTA from IN1
Press numerical key which will set the first digit of a code (D1 digit)
Wait until the reader generates two short beeps as the prompt signal
Press numerical key which will set the second digit of a code (D2 digit)
Once the previous step has been completed the reader automatically ends the
programming procedure and goes to normal operation
Содержание PRT12 v1.3
Страница 1: ...PRT12 v1 3 RFID PIN Outdoor Access Terminal Firmware v75 6 Installation and Programming Guide ...
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ... This page intentionally left blank ...
Страница 36: ......
Страница 39: ...Notes No Fault description filled out by the customer Date of repair filled out by the service 1 2 3 4 5 ...