background image

MCT12E Operating Manual 

  

05.10.2020 

 

6/14 

 

IN2 

Blue 

 

IN2 input line 

IN3 

White-yellow 

 

IN3 input line 

RS485 A 

Brown 

Brown 

RS485 bus, line A 

RS485 B 

Green-white 

White 

RS485 bus, line B 

CLK 

White 

Green 

CLK line 

DTA 

Green 

Yellow 

DTA line 

TMP 

Yellow 

Pink 

Tamper contact 

TMP 

Grey 

Grey 

Tamper contact 

IO1 

Yellow-brown 

 

IO1 output line 

IO2 

Green-brown 

 

IO2 output line 

REL1-NC 

Grey-pink 

 

REL1 relay normally closed contact 

REL1-COM 

Red-blue 

 

REL1 relay common contact 

REL1-NO 

Violet 

 

REL1 relay normally opened contact 

 

 

Fig. 4 Programming jumpers 

Содержание MCT12E

Страница 1: ...Roger Access Control System MCT12E Operating Manual Product version 1 1 Firmware version 1 0 4 or newer Document version Rev A...

Страница 2: ...ly IO versions Power supply The terminal requires power supply voltage in range of 11 15VDC It can be supplied from MCX2D MCX4D expander of MC16 PAC KIT from MC16 access controller e g TML output or f...

Страница 3: ...matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded twiste...

Страница 4: ...icates access granting LED SYSTEM Orange LED indicates card reading and can signal other system functions including device malfunction Note Synchronic pulsing of LED indicators signifies lost communic...

Страница 5: ...rds EM125kHz proximity cards are widely used in office buildings If it is necessary to ensure higher level of security then MIFARE card readers e g MCT12M are recommended The technical characteristics...

Страница 6: ...85 bus line B CLK White Green CLK line DTA Green Yellow DTA line TMP Yellow Pink Tamper contact TMP Grey Grey Tamper contact IO1 Yellow brown IO1 output line IO2 Green brown IO2 output line REL1 NC Gr...

Страница 7: ...MCT12E Operating Manual 05 10 2020 7 14 Fig 5 MCT12E installation...

Страница 8: ...must be connected with any wire Device can be cleaned by means of wet cloth and mild detergent without abrasive components In particular do not clean with alcohols solvents petrol disinfectants acids...

Страница 9: ...MCT device firmware version RS485 communication channel and serial port with RUD 1 interface 3 Click Connect the program will establish connection and will automatically display Configuration tab 4 En...

Страница 10: ...h readers Selected input must be connected to synchronisation output of another reader When set to 0 then synchronisation is disabled Typical numbering is 1 IN1 2 IN2 and 3 IN3 Range 0 3 Default value...

Страница 11: ...disabled Range 0 100 Default value 100 Input types IN1 IN2 IN3 Parameter defines the type of input line Range 1 NO 2 NC Default value 1 NO Input comments IN1 IN2 IN3 Parameter defines any text or comm...

Страница 12: ...the next digit Zero digit is emulated with 10 readings Example Programming of ID 101 address with card readings 1 Read card 1 time and wait for two beeps 2 Read card 10 times and wait for two beeps 3...

Страница 13: ...5 bus between controller and reader IP Code IP65 Environmental class according to EN 50133 1 Class IV outdoor general conditions temperature 25 C to 60 C relative humidity 10 to 95 no condensation Dim...

Страница 14: ...ctric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste cont...

Отзывы: