MCT12E Operating Manual 

  

05.10.2020 

 

2/14 

 

1.

 

D

ESIGN AND APPLICATION

 

The  MCT12E  is  a  series  of  access  terminals  dedicated  to  RACS  5  system.  Depending  on  their  versions, 
devices enable identification of users by PINs and/or EM125kHz (UNIQUE) proximity cards. 
MCT12  is  connected  to  access  controller  through  RS485  interface.  Terminal  can  be  installed  in  outdoor 
locations without any additional protection measures. 
 

Table 1. MCT12E versions 

Version 

MCT12E 

MCT12E-BK 

MCT12E-IO 

MCT12E-BK-IO 

Keypad 

Yes 

Yes 

Inputs 

 

Relay output 

 

Transistor outputs 

 

Characteristics 

  RACS 5 system access terminal 

  EM125kHz (UNIQUE) proximity cards 

  3 LEDs indicators 

  Buzzer 

  Silicone keypad with backlight* 

  2 function keys* 

  3 NO/NC inputs** 

  2 transistor outputs** 

  1 relay output** 

  RS485 interface 

  Tamper protection 

  Outdoor environment 

  Connection cable 

** not in 

–BK versions 

*** only 

–IO versions 

Power supply 

The terminal requires power supply voltage in range of 11-15VDC. It can be supplied from MCX2D/MCX4D 
expander  of  MC16-PAC-KIT,  from  MC16  access  controller  (e.g.  TML  output)  or  from  dedicated  power 
supply unit. The supply  wire diameter must be selected in such  way  that the  voltage drop between supply 
output and the device would be lower than 1V. The proper wire diameter is especially critical when device is 
located  in  long  distance  from  the  supply  source.  In  such  a  case  the  use  of  dedicated  power  supply  unit 
located close to the device should be considered. When separate power supply unit is used then its minus 
should be connected to controller’s GND by means of signal wire with any diameter. It is recommended to 
use UTP cable for connection of device to controller. The table below shows maximal UTP cable lengths in 
relation to the number of wires used for power supply. 
 

Table 2. Power supply cabling 

Number of UTP wire pairs for power supply 

Maximal length of power supply cable 

150m 

300m 

450m 

600m 

 

Содержание MCT12E

Страница 1: ...Roger Access Control System MCT12E Operating Manual Product version 1 1 Firmware version 1 0 4 or newer Document version Rev A...

Страница 2: ...ly IO versions Power supply The terminal requires power supply voltage in range of 11 15VDC It can be supplied from MCX2D MCX4D expander of MC16 PAC KIT from MC16 access controller e g TML output or f...

Страница 3: ...matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded twiste...

Страница 4: ...icates access granting LED SYSTEM Orange LED indicates card reading and can signal other system functions including device malfunction Note Synchronic pulsing of LED indicators signifies lost communic...

Страница 5: ...rds EM125kHz proximity cards are widely used in office buildings If it is necessary to ensure higher level of security then MIFARE card readers e g MCT12M are recommended The technical characteristics...

Страница 6: ...85 bus line B CLK White Green CLK line DTA Green Yellow DTA line TMP Yellow Pink Tamper contact TMP Grey Grey Tamper contact IO1 Yellow brown IO1 output line IO2 Green brown IO2 output line REL1 NC Gr...

Страница 7: ...MCT12E Operating Manual 05 10 2020 7 14 Fig 5 MCT12E installation...

Страница 8: ...must be connected with any wire Device can be cleaned by means of wet cloth and mild detergent without abrasive components In particular do not clean with alcohols solvents petrol disinfectants acids...

Страница 9: ...MCT device firmware version RS485 communication channel and serial port with RUD 1 interface 3 Click Connect the program will establish connection and will automatically display Configuration tab 4 En...

Страница 10: ...h readers Selected input must be connected to synchronisation output of another reader When set to 0 then synchronisation is disabled Typical numbering is 1 IN1 2 IN2 and 3 IN3 Range 0 3 Default value...

Страница 11: ...disabled Range 0 100 Default value 100 Input types IN1 IN2 IN3 Parameter defines the type of input line Range 1 NO 2 NC Default value 1 NO Input comments IN1 IN2 IN3 Parameter defines any text or comm...

Страница 12: ...the next digit Zero digit is emulated with 10 readings Example Programming of ID 101 address with card readings 1 Read card 1 time and wait for two beeps 2 Read card 10 times and wait for two beeps 3...

Страница 13: ...5 bus between controller and reader IP Code IP65 Environmental class according to EN 50133 1 Class IV outdoor general conditions temperature 25 C to 60 C relative humidity 10 to 95 no condensation Dim...

Страница 14: ...ctric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste cont...

Отзывы: