Roger Technology Swing Gate Brushless B70-2DCHP Control Panel
Quick Start Guide Extended Mode
2
ROGER BRUSHLESS B70/2DCHP Control panel when using FES180/PHOTO180 photocells
The photocells are in pairs, one transmitter and one receiver. They should be mounted 500-600 mm from the ground and face each other
level. Each photocell regardless of type has a 24VAC supply.
The receiving photocell does the switching on and off to the control panel. If the transmitting beam can reach the receiving photocell, there
will be a completed circuit to the main panel and the gate/s will function. If the beam is broken, during operation of closing, the gates will stop
and reopen.
If you are using two pairs of photocells as pictured, the receivers should be crossed on opposite sides so that you do not have two receivers at
the same side. The set on the gate posts (3) are on the outside of the gates.
For this purpose 5 core BT type cable is recommended for use. (CW1128 with conduit) Follow the wiring diagram provided to wire both the
receiver and transmitting photocells. At the control box end, wire the colour coded cables up as per the diagram provided showing a typical
photocell placement.
When the photocells are working and correctly aligned, you should hear a clicking sound from the transmitter when the beam is broken
intermittently. Once wired, place the covers over the photocells and secure the fixing screw. Fill any cable gaps with silicone to prevent
insects from entering the device and interfering with it.
FES180/FOTO180
BIG1/F, photocells.
Jumpers should not
be used.
ROGER B70/2DCHP
Control panel.
Where required,
enable these functions.
See the main manual B70-2DCHP for
other photocell types.