 5 - 

UNAC Guide No. 2- July 2005 

 

MD 

Ann. 1

 

Type of risks 

 

Evaluation criteria and solutions to be adopted 

(Tick the box corresponding to the solution adopted)

 

1.3.7 
1.3.8 
1.4 

Mechanical risks due to 
movement of the leaf. 

 

[7] Dragging of the 
hands on the hinges side 
edge (Figure 1, risk D). 
 
 
 
 
[8] Dragging of the feet 
on the lower edge 
(Figure 1, risk E). 
 
 
[9] Dragging of the 
hands on the drive unit 
(Figure 1, risk F). 
 
[10] Dragging, hooking 
and cutting due to the 
shaping of the mobile 
leaf (Figure 1, risk G).

 

 
 

 

F

 Check that there is a clearance > 25 mm, 

 
or: 
 

F

 attach guards that prevent fingers from being inserted (for example a 

rubber strip). 
 

F

 The clearance between the gate and ground must prevent the risk of 

dragging of the feet. 

 

N.B. Should, due to the slope of the ground, the clearance vary, guards 
should be attached (e.g. rubber strips). 

 

F

 If the distances between the drive unit and the leaf vary, check on the 

presence of a clearance > 25 mm, or attach guards (e.g. covers or strips in 
rubber).  
 

F

 Eliminate or protect any sharp edges, handles, projecting parts etc. (for 

example by means of covers or strips in rubber). 
 

 

 

 
 
 
1.5.1 
1.5.2 
 
 
 
 
 
 
 
1.5.10 
1.5.11 

Electrical and electromagnetic 
compatibility risks 

 

[11] Direct and indirect 
contacts. 
Dispersion of electrical 
energy. 

 
 

 
 
 
[12] Risks relating to 
electromagnetic 
compatibility. 

 

 

 

 

F

 Use CE-marked components and materials pursuant to the Low Voltage 

Directive (73/23/EEC). 

F

 Carry out the electrical connections, connection to the mains, earth 

connections and relevant checks, in accordance with current regulations and 
as indicated in the installation manual of the drive unit. 
 

N.B. If the electrical supply line is already set up (via both a socket and a 
connector block), declarations of conformity to Italian law no. 46/90 are not 
necessary. 
 

F

 Use CE-marked components pursuant to the EMC Directive (89/336/EEC). 

Carry out the installation as indicated in the manual for installation of the drive 
unit. 

 
 
 
 
 
 
1.2 
 
 
 
 
1.5.3 
 
 
 
 
 
1.2.3 
1.2.4 
 
 
 
 

Safety and reliability of 
drive unit and control and 
safety devices. 

 

 

[13] Safety conditions in 
the event of 
malfunctioning and 
power failure. 

 

[14] Energy types other 
than electrical energy 

 

 
 
 
[15] Actuation and 
disabling of the drive 
unit. 
 
[16] Power supply 
switch. 

 
 
 
 

 

F

 Use drive units which comply with the standard EN 12453 and safety 

devices which comply with the standard EN 12978. 
 

 

 

F

 If hydraulic drive units are used, they must comply with the standard EN 

982; or 

 

F

 if pneumatic drive units are used, they must comply with the standard EN 

983. 

 

F

 Check that, after a fault or power failure, the drive unit restarts safely 

without creating hazardous situations. 
 
 

F

 Install an omnipolar switch for electrical insulation of the door/gate, in 

accordance with current laws. This switch must be positioned and protected 
against accidental or unauthorised actuation. 

Содержание B70-2DCHP

Страница 1: ...cables XYZ and earth to the XYZ points inside the control panel for each motor respecting that brushless motors need a minimum of 2 5mm cross section cable size If the cables to be connected to the motor are extended over 10 metres in total length a 4 0mm cross section cable must be used In the case on just 1 motor connect to Step 3 Connect the power supply to the control panel Press the test butt...

Страница 2: ...rossed on opposite sides so that you do not have two receivers at the same side The set on the gate posts 3 are on the outside of the gates For this purpose 5 core BT type cable is recommended for use CW1128 with conduit Follow the wiring diagram provided to wire both the receiver and transmitting photocells At the control box end wire the colour coded cables up as per the diagram provided showing...

Страница 3: ... positions of the collars by swinging the gate open closed with the motor unlocked Step Step 6 You should now be ready to carry out the stroke programming sequence But first you should check that the motors are traveling in the correct direction in relation to the control panel To do this it will be necessary to give the panel a brief open or close command and compare the command to the movement o...

Страница 4: ...ogramming press the PROG button for 4 s the display will show AP P at this point you can programme the stroke by pressing the PROG button again or by pressing the radio control button enabled by the step by step function The display shows the indication AUTO and motor 1 starts opening after the phase shift time Programming is performed automatically Wait for the completion of the cycles avoiding c...

Страница 5: ...red codes NOTE it s recommended to delete all codes at the first installation before starting storing codes Step 9 Test the system You can now test run the system with the fob If necessary reduce the impact force level with the menus 30 to 33 in the parameters These settings are explained in the manufacturers B70 2DCHP manual Step 10 Add in the necessary safety photocells safety edges and other de...

Страница 6: ...e 6 Connecting gate release devices Volt free release connections only The communication part of the intercom must use its own power supply Check that powered your devices will accept 24VDC Connection of the inductive loop detector PD132 230VAC for use as an exit device All dips off Road Loop ...

Страница 7: ...nology Swing Gate Brushless B70 2DCHP Control Panel Quick Start Guide Extended Mode 7 Connecting magnetic locks Connecting a 12V time clock GL Series Mag locks wiring detail N C White COM Green Not normally used ...

Страница 8: ...r safety if necessary integrating those in the manual for installation of the door gate and give the user a copy Compile the proof book and give the user a copy see facsimile in Annex 1 Draft the EC declaration of conformity see facsimile in Annex 2 and give the user a copy Fill in the label or plate with CE marking and attach it to the motorised door gate N B The technical file must be held and m...

Страница 9: ...E MACHINERY DIRECTIVE 98 37 EEC AND THE STANDARDS EN 13241 1 EN 12453 EN 12445 The risks listed below follow the sequence of the installation process These risks are those which are commonly present in motorised doors gates systems According to the various situations consideration therefore has to be made of any possible additional risks and exclude those which are not applicable The solutions to ...

Страница 10: ... force should be measured one leaf at a time Check that the values measured by the instrument are below those indicated in the graph Carry out the measurements in the following points L 50 300 and 500 mm H 50 mm at mid height of the leaf and at the height of the leaf minus 300 mm max 2500 N B The measurement should be repeated three times in each point and the average value considered The graph in...

Страница 11: ...tective device in accordance with the standard EN 12978 for example a sensitive edge and repeat the measurement 5 Impact in the area of closure Figure 1 risk C F Install a pair of photocells recommended height 500 mm so as to sense the presence of the test parallelepiped height 700 mm positioned as illustrated N B The test specimen for presence sensing is a parallelepiped 700 x 300 x 200 mm with 3...

Страница 12: ... Use CE marked components and materials pursuant to the Low Voltage Directive 73 23 EEC F Carry out the electrical connections connection to the mains earth connections and relevant checks in accordance with current regulations and as indicated in the installation manual of the drive unit N B If the electrical supply line is already set up via both a socket and a connector block declarations of co...

Страница 13: ...safety devices installed 1 7 1 1 7 2 1 7 3 1 7 4 1 6 1 1 1 2 Integration principles for safety and information 20 Signalling equipment 21 Warnings 22 Marking 23 Operating instructions 23 Maintenance 24 Unprotected residual risks F A flashing light should be installed in a visible position to indicate movement of the leaf F Traffic lights can be installed to control vehicle traffic F Reflectors can...