 3 - 

UNAC Guide No. 2- July 2005 

MD 

Ann. 1

 

Type of risks 

 

Evaluation criteria and solutions to be adopted 

(Tick the box corresponding to the solution adopted)

 

1.3.7 
1.3.8 
1.4 

Mechanical risks caused by the movement of the gate (see references in Figure 1). 

 

F

 

CAUTION – If the door/gate is used solely with hold-to-run controls (and meets the requirements of the 

standard EN 12453), the danger points listed below do not have to be protected.  

F

 CAUTION – If protective devices are installed (in accordance with the standard EN 12978) which prevent in 

all cases contact between the moving leaf and persons (for example photoelectric barriers, presence sensing 
devices), it is not necessary to measure the operating forces.

 

 
 

 
[3] Impact and crushing on the main closing 
edge (Figure 1, risk A). 

 

F

 Measure the closure forces (by means of the 

special instrument required by the standard EN 
12445) as illustrated. 
In the case of gates with two leaves, the closure 
force should be measured one leaf at a time. 
Check that the values measured by the instrument 
are below those indicated in the graph. 
Carry out the measurements in the following points: 
L = 50, 300 and 500 mm; 
H = 50 mm, 
      at mid-height of the leaf and 
      at the height of the leaf minus 300 mm (max 
2500). 
 

N.B. The measurement should be repeated three 
times in each point and the average value 
considered. 

 
 
The graph indicates the maximum values of the 
dynamic, static and residual operating forces in 
relation to the various positions of the leaf. 
 

N. B. With reference to the measurement points with 
L = 50, 300 and 500 mm, the maximum dynamic 
force value permitted is 400 N. 

 
 

F

 

If the values of the forces are higher, install a 

protective device in accordance with the standard 
EN 12978 (for example a sensitive edge) and repeat 
the measurement. 

 

N. B. The dynamic force can be reduced, for 
example, by reducing the speed of the leaf or using 
a sensitive edge with high elastic deformation. 
 

                                                   

 

 

 

 

Leaves with overlapping and delayed closure 

 
 

 

 

                     Leaves with simultaneous closure 

                     

                   

 

 

Force 

Dynamic force      
IMPACT

Static force           
CRUSHING

 

time  

Protective Device

 

Protective Device

Содержание B70-2DCHP

Страница 1: ...cables XYZ and earth to the XYZ points inside the control panel for each motor respecting that brushless motors need a minimum of 2 5mm cross section cable size If the cables to be connected to the motor are extended over 10 metres in total length a 4 0mm cross section cable must be used In the case on just 1 motor connect to Step 3 Connect the power supply to the control panel Press the test butt...

Страница 2: ...rossed on opposite sides so that you do not have two receivers at the same side The set on the gate posts 3 are on the outside of the gates For this purpose 5 core BT type cable is recommended for use CW1128 with conduit Follow the wiring diagram provided to wire both the receiver and transmitting photocells At the control box end wire the colour coded cables up as per the diagram provided showing...

Страница 3: ... positions of the collars by swinging the gate open closed with the motor unlocked Step Step 6 You should now be ready to carry out the stroke programming sequence But first you should check that the motors are traveling in the correct direction in relation to the control panel To do this it will be necessary to give the panel a brief open or close command and compare the command to the movement o...

Страница 4: ...ogramming press the PROG button for 4 s the display will show AP P at this point you can programme the stroke by pressing the PROG button again or by pressing the radio control button enabled by the step by step function The display shows the indication AUTO and motor 1 starts opening after the phase shift time Programming is performed automatically Wait for the completion of the cycles avoiding c...

Страница 5: ...red codes NOTE it s recommended to delete all codes at the first installation before starting storing codes Step 9 Test the system You can now test run the system with the fob If necessary reduce the impact force level with the menus 30 to 33 in the parameters These settings are explained in the manufacturers B70 2DCHP manual Step 10 Add in the necessary safety photocells safety edges and other de...

Страница 6: ...e 6 Connecting gate release devices Volt free release connections only The communication part of the intercom must use its own power supply Check that powered your devices will accept 24VDC Connection of the inductive loop detector PD132 230VAC for use as an exit device All dips off Road Loop ...

Страница 7: ...nology Swing Gate Brushless B70 2DCHP Control Panel Quick Start Guide Extended Mode 7 Connecting magnetic locks Connecting a 12V time clock GL Series Mag locks wiring detail N C White COM Green Not normally used ...

Страница 8: ...r safety if necessary integrating those in the manual for installation of the door gate and give the user a copy Compile the proof book and give the user a copy see facsimile in Annex 1 Draft the EC declaration of conformity see facsimile in Annex 2 and give the user a copy Fill in the label or plate with CE marking and attach it to the motorised door gate N B The technical file must be held and m...

Страница 9: ...E MACHINERY DIRECTIVE 98 37 EEC AND THE STANDARDS EN 13241 1 EN 12453 EN 12445 The risks listed below follow the sequence of the installation process These risks are those which are commonly present in motorised doors gates systems According to the various situations consideration therefore has to be made of any possible additional risks and exclude those which are not applicable The solutions to ...

Страница 10: ... force should be measured one leaf at a time Check that the values measured by the instrument are below those indicated in the graph Carry out the measurements in the following points L 50 300 and 500 mm H 50 mm at mid height of the leaf and at the height of the leaf minus 300 mm max 2500 N B The measurement should be repeated three times in each point and the average value considered The graph in...

Страница 11: ...tective device in accordance with the standard EN 12978 for example a sensitive edge and repeat the measurement 5 Impact in the area of closure Figure 1 risk C F Install a pair of photocells recommended height 500 mm so as to sense the presence of the test parallelepiped height 700 mm positioned as illustrated N B The test specimen for presence sensing is a parallelepiped 700 x 300 x 200 mm with 3...

Страница 12: ... Use CE marked components and materials pursuant to the Low Voltage Directive 73 23 EEC F Carry out the electrical connections connection to the mains earth connections and relevant checks in accordance with current regulations and as indicated in the installation manual of the drive unit N B If the electrical supply line is already set up via both a socket and a connector block declarations of co...

Страница 13: ...safety devices installed 1 7 1 1 7 2 1 7 3 1 7 4 1 6 1 1 1 2 Integration principles for safety and information 20 Signalling equipment 21 Warnings 22 Marking 23 Operating instructions 23 Maintenance 24 Unprotected residual risks F A flashing light should be installed in a visible position to indicate movement of the leaf F Traffic lights can be installed to control vehicle traffic F Reflectors can...

Отзывы: