Integrating the laser system
38
PowerLine E Air
4.2.4.3
Shutter interlock, hardware circuit
4.2.5
Digital outputs laser control
Target value: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24V DC
Signal logical 1 corresponds to: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +24V (+20 ... +30V)
Signal logical 0 corresponds to: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0V @ R
load
≤
100 k
Ω
Max. load: (transistor output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mA
Short-circuit proof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . yes
4.2.5.1
Shutter closed
4.2.5.2
Shutter open
You can connect an interlock circuit, e.g. door
check, by a safety switch on the laser class 1
safety area.
The output resistance must not exceed 6 Ohm per
channel.
Please pay special attention to potential separa-
tion.
This output is set when the shutter is safely closed
and the laser is ready for operation.
This signal output is also available on -X46 (see
Section "4.3, External control panel -X46" on
page 43).
This output will be set if the shutter is safely open
and the laser is ready for operation.
This signal output is also available on -X46 (see
Section "4.3, External control panel -X46" on
page 43).
-X42a : 22
-X42a : 23
-X42a : 24
-X42a : 25
+24V
0V24
-X42b : 7
-X42b : 4
-X42b : 8
+24V
-X42b : 7
-X42b : 19
-X42b : 8
+24V
Содержание PowerLine E Air 10
Страница 1: ...THE MARK OF EXCELLENCE PowerLine E Air Maintenance and Integration Manual Version 1 3 7...
Страница 2: ......
Страница 8: ...viii...
Страница 26: ...Safety 16 PowerLine E Air...
Страница 40: ...Spare parts 30 PowerLine E Air...
Страница 71: ...Integrating the laser system PowerLine E Air 61 FIG 47 PowerLine E Air with RS RM10 G4 marking head...
Страница 74: ...Integrating the laser system 64 PowerLine E Air FIG 50 19 plug in PC 2HE...
Страница 76: ...Integrating the laser system 66 PowerLine E Air...