![Rofin PowerLine E Air 10 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/rofin/powerline-e-air-10/powerline-e-air-10_maintenance-and-integration-manual_1476994046.webp)
Integrating the laser system
36
PowerLine E Air
4.2.3.4
Error PC (system error)
1
Attention
Effective as of VLM marking sofware version 4.4:
4.2.3.5
Error laser system
4.2.3.6
M-function
As soon as an error occurs in the marking
software, this output has logical signal 1 (+24V).
Signal logical 1 for galvo check error, program
sequence error and external error. The signal is
automatically removed again.
This output is set if an error is reported.
3
Note
See also the 'Operating status and fault displays'
chapter in the Operator’s Manual of the laser sys-
tem.
This signal output is also available on -X46 (see
Section "4.3, External control panel -X46" on
page 43).
M-function outputs can be set by the VLM or
VMC2 marking program. They serve to control
actuators, e.g. at a handling unit. The signals are
distributed to two plug connectors.
3
Note
See VLM manual or VMC2 software description.
8 Bit M functions are available:
–
Bit 8 and 9 on -X42b
–
Bit 10 to 15 on -XC3a
-X42b:
-X42b:
-XC3a:
-XC3a:
-XC3a:
-XC3a:
-XC3a:
-XC3a:
n=
1
2
9
10
11
12
13
14
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
-X42b : 7
-X42b : 1
-X42b : 8
+24V
-X42b : 7
-X42b : 17
-X42b : 8
+24V
-X42b : 7
-X42b : n
-X42b : 8
+24V
-XC3a : 15
-XC3a : n
-XC3a : 7
+24V
Содержание PowerLine E Air 10
Страница 1: ...THE MARK OF EXCELLENCE PowerLine E Air Maintenance and Integration Manual Version 1 3 7...
Страница 2: ......
Страница 8: ...viii...
Страница 26: ...Safety 16 PowerLine E Air...
Страница 40: ...Spare parts 30 PowerLine E Air...
Страница 71: ...Integrating the laser system PowerLine E Air 61 FIG 47 PowerLine E Air with RS RM10 G4 marking head...
Страница 74: ...Integrating the laser system 64 PowerLine E Air FIG 50 19 plug in PC 2HE...
Страница 76: ...Integrating the laser system 66 PowerLine E Air...