background image

Programming modes and programming procedures of the Lokmaus®2

Before you start to program a loco decoder you should read the instruction to find out what parameters

and which values can be programmed and which kind of programming mode is required. An overview

for the ROCO decoders and the decoders of other manufacturers that we have tested you find in the

compatibility-list on page 33. There you find a list of the facilities of the ROCO decoders too.

Using the Lokmaus®2 you can take advantage of all the features of a loco decoder including the pro-

grammation. The Lokmaus offers two modes of programmation: the standard and the professional

mode. Using the standard mode you can programm the loco address, the minimum speed, the accele-

ration and deceleration, the maximum speed ant the CV29. Using the professional mode you can pro-

gram all important settings of the decoders by programming the CVs from 01 to 99 indicating values

from 00 to 99.

IMPORTANT: there must be only one decoder in the system during the programming procedure

(except the digital turnout drive. 42624). If there are more than one loco or switch decoder on the track

or connected to the amplifier all decoders are programmed simultaneously including switch-decoders!

By that way e.g. all decoders could be programmed to the same address!

Therefore it is the best way to program loco and switch decoders on a separate programming-track. So

first unplug all feeding tracks of your layout, second plug the programming track and then start the pro-

gramming procedure. Instead of unplugging you can install a two-pole-switch that cuts the feeding of

the driving area of your layout and only feeds the programming track (see fig. 4 on page 37).

IMPORTANT:

Be careful with switch decoders, they could be damaged that way!

Standard Programming Procedure

In this mode you can change the most important parameters of a loco such as the address, minimum

speed, acceleration and deceleration delay and the maximum speed. Pressing ‘P’ and one of the functi-

on buttons ‘star’ or ‘F1’ to ‘F4’ leads you into the standard programming mode. By the same procedure

you select the parameter that you want to program (see the list below).

Meanwhile you press the two buttons the display shows ‘SP’ and all trains on the layout stop. The two

points of the display flash alternately to indicate the standard programming mode. After you released

the two buttons the mouse indicates in the display the default value for the selected parameter (connec-

ted to an amplifier or central unit that can read out the decoder it indicates the actual setting of the deco-

der). If you want to change this value e.g. the loco address you select an othere setting by the ‘up’ or

‘down’ button. Pressing the button ‘P’ you confirm the selection and start the programming procedure

that writes the setting into the decoder. This procedure takes some time depending on the programming

modes that are executed. The display indicates this procedure showing ‘P’. After this procedure the

Lokmaus®2 returns automatically to the normal state and the locos restart to run. By pressing ‘STOP’

you can return to the normal state without writing something into the decoder.

IMPORTANT:

Pay attention to the valid range for the parameters! Please read the instruction of the loco

decoder. A list of the features of the ROCO decoders you find on page 34.

This programming mode can be deactivated by the menu C3 – so it can’t be used unintentionally by chil-

dren – see on page 28.

‘P’ + ‘star’ programs the address,

value 01 to 99, default is 03

‘P’ + ‘F1’ defines the minimum speed,

value 01 to 99, default is 08

‘P’ + ‘F2’ defines the acceleration delay,

value 01 to 99, default is 04

‘P’ + ‘F3’ defines the deceleration delay,

value 01 to 99, default is 04

‘P’ + ‘F4’ defines the maximum speed

(only can be programmed if the decoder is load regulated)

value 01 to 99, default is 15

‘P’ + ‘STOP’ programs the CV29 that contains basic settings of the decoder

value 01 to 99, default is 04

24

Содержание LOKMAUS 2

Страница 1: ...Programming the Digital Turnout Drive 42624 26 Short Circuit and Overload 26 The Booster 10762 26 Using one or more Boosters 10762 26 Analogue Locos Locos without Digital Decoder on Digital Tracks 27 Compatibility of the new System RocoNet to the old Digital System Maus Bus 27 Compatibility of Control Devices and Decoders 27 The Menu System of the Lokmaus 2 28 Combination of Digital and Non Digita...

Страница 2: ...the loco q two digits LED display of the selected address or other information q 14 28 and 128 speed steps mode for all locos together or individually selectable for any loco sepa rately q emergency stop that stops the complete layout and cuts current supply q autoconfiguration of the RocoNet address q the system koordinates 31 devices such as the ROCO Lokmaus 2 the switch keyboard etc q setup men...

Страница 3: ...manufacturers may not have an autoconfiguration of the RocoNet address So you have to set the address by a setup procedure How this is done please read the instruction of those devi ces or contact the manufacturer If it is necessary to have an adaptor plug please take a look at www roco co at digital if there is a plug offered by ROCO ATTENTION If you make your own adaptor plug you must strictly a...

Страница 4: ...a digitally controlled smoke generator di gital uncoupler sound etc Therefore on most of the locos the function keys don t control nothing To operate those additional functions the loco must be equipped with a special deoder or an additional function decoder For the future it is ROCO s plan to raise the playworth of the railroad by adding functions to locos and cars So these functions already have...

Страница 5: ... that means e g all locos run with 28 speed steps The second defines the speed steps different for each loco e g loco 04 runs with 28 speed step loco 17 with 128 and loco 98 only with 14 The factory default setting is 28 speed steps for all locomotives this setting is restored by the system reset using C7 This setup is done by the menu C6 see page 29 You can define the ge neral mode to 14 speed st...

Страница 6: ...arameters of a loco such as the address minimum speed acceleration and deceleration delay and the maximum speed Pressing P and one of the functi on buttons star or F1 to F4 leads you into the standard programming mode By the same procedure you select the parameter that you want to program see the list below Meanwhile you press the two buttons the display shows SP and all trains on the layout stop ...

Страница 7: ...s to develop a device that is more powerful and supports to read the decoder If you use the Lokmaus 2 together with a LZ100 and LV101 by Lenz then you can read out the loco decoder already today If you select F4 to write the decoder then you must indicate the value you want to program by the but tons up and down By principle all values from 00 to 99 are programmable but most of the decoders only s...

Страница 8: ...cedure the Lokmaus 2 automatically return to the normal operation Release the green programming wire from the track The turnout drive now can be operated by the button F1 During this programming procedure further digital turnout drives 42624 may stay installed because the turnout drive takes the address only in case that the green programming wire is attached to the track Be careful with switch de...

Страница 9: ...racks The second generation of the ROCO digital system does not support controlling a loco without a digital decoder also the old digital is cool system didn t The reason is that a loco without digital decoder on a digital layout causes an enormeously bothering high frequency noise There is also the danger that small motors originally N scale motors that are installed in some small H0 locos could ...

Страница 10: ...hile you re plug the Lokmaus 2 The display shows you the first menu C0 Using the buttons up and down you can also select other menus e g C3 Push P again and the display shows the actual value of C3 By the buttons up and down you can change this value of C3 and pushing P you confirm and activate your input Pushing STOP you quit this menu The following list tells you the various menus and explains t...

Страница 11: ...the values for C9 and the programming methods you select by this values C9 AO RG CV PM C9 AO RG CV PM 00 08 on 01 on 09 on on 02 on 10 on on 03 on on 11 on on on 04 on 12 on on 05 on on 13 on on on 06 on on default 14 on on on 07 on on on 15 on on on on AO address only RG register mode CV CV direkt PM paged mode Default is 14 at the Lokmaus 2 that are included in the starting sets 41203 and 41212 ...

Страница 12: ...nd all digital locos get digital informations and could react according to those commands This effect can be avoided by installing a pass over section as shown in fig 7 on page 38 This section must be longer than the longest train that passes over it It is insulated on both ends on both sides A train that passes over this section only con nects the pass over section to the digital or to the DC sys...

Страница 13: ...co is the programming of the CV29 must be corrected to change the inversed sense of driving How to program the CV29 you read on page 25 headlights of the pilot car e g By programming the CV29 you must change the sense of driving of the ICE don t match direction of the pilot car Put the pilot car without loco on the programming track How to program the CV29 you read on page 25 the speed step mode c...

Страница 14: ...you have disabled the au toconfiguration you must correct the device address yourself How to change the device address you can read on page 28 error code E7 The actual RocoNet address of the Lokmaus 2 is not addressed This error message may occur because you added more devices to the system than defined in the menu C8 How you raise the number of devices you read on page 29 This error message can a...

Страница 15: ...ok ok ok Lenz LE100 ok ok LE111N ok ok ok ok LE131N ok ok ok ok MRC AC310 ok Soundtraxx DSD150 ok ok System One CH155 ok ok ok Zimo MX61R N ok ok ok ok Devices of other brands as input devices at the RocoNet manufacturer device autoconfiguration comment Lenz LH100 you need an adaptor plug LH200 ok can t be master LI100 you need an adaptor plug Arnold 81210 you need an adaptor plug 81220 you need a...

Страница 16: ... 10740 see page 25 10741 only 14 speed steps Proprietes du décodeur ROCO LENZ Lokdecoder CV valeurs paramêtre limitations 01 01 99 adresse de la locomotive pas pour l ICE 215 de 41100 02 01 15 vitesse minimale pas pour le décodeur 10740 03 01 31 vitesse de accelération pas pour le décodeur 10740 04 01 31 vitesse de décélération pas pour le décodeur 10740 05 01 15 vitesse maximale seulement ROCO 10...

Отзывы: