InSpec Remote I/O HUB (ATEX, IECEx)
Section 9: Instrument Specifications
27
Instrument Specifications
GENERAL SPECIFICATIONS
DESIGN AREA
ITEM
DESCRIPTION
Physical
Size (mm)
440mm x 565mm x 240mm (W x H x D) Approx.
17½” x 22¼” x 9½” (W x H x D) Approx.
Weight
50 kg approx.
Wire Connections
Screw Terminals:
22–12 AWG (0.5 to 2.5mm²)
Earth Bus Bar:
22–12 AWG (0.5 to 2.5mm²), 16mm² when cable lug
used.
RIO-xxx Modules & Relay Modules:
24–14 AWG (0.25 to 2.5mm²)
Operating
Environment
Equipment Class
I
Installation Category
II
Pollution Degree
3
1
(Jiskoot Remote I/O Hub only)
Operating Temperature
AC Powered:
-20°C to +50°C (-4°F to +122°F)
DC Powered:
-20°C to +60°C (-4°F to +140°F)
Relative Humidity
80% up to 31°C decreasing linearly to 50% at 40°C
IP Rating
IP66
Altitude
2000 metres max. (6562 feet)
Power Supply
Voltage, Frequency
AC Powered:
100 to 240 V AC, 50/60 Hz
DC Powered:
24V DC ± 10%
Power Consumption
AC Powered:
80 Watts Max. (All options fitted)
DC Powered:
30 Watts Max. (All options fitted)
Remote I/O Modules
Quantity
4 max.
Types
RIO-DIO :
Digital Input/Output Module
RIO-PUL :
Pulse/Frequency Input Module
RIO-ANI :
Analogue (4-20mA) Input Module
RIO-ANO :
Analogue (4-20mA) Output Module
Relay Outputs
Quantity
4
Contact Form
Solid State Relay – SPST – NO
Installation Category
III
Max. Switching Voltage 250V AC, 30V DC
Max. Switching Current 1 Amp
Intrinsically Safe
Interfaces
Quantity 2
max.
Types
Either 2 Ch. CanWeigh or 2/4 Ch. CanHigh
Communications
Quantity
1
Type Either:
Ethernet 10/100 direct wire (100m max.), or
Ethernet SHDSL Extender (15km max.)
1
Pollution Degree 3 – Normally only non-conductive POLLUTION occurs. Occasionally, however, a
temporary conductivity caused by condensation must be expected.