MC_HOME_REF_WITH_ABS
MC_HOME_REF_WITH_ABS (2) homing procedure performs a homing
operation against Home switch, plus fine Ref Pulse signal. The actual motion
sequence is dependent on the home switch, limit switch configuration, and the
actual status for the switches before homing starts—that is, when the
MC_Home function block is issued.
Scenario 1: Moving part at right (positive) side of Home switch before homing starts
The homing motion sequence for this scenario is as follows:
1. Moving part moves to its left side (in negative direction);
2. When Home Abs switch is detected, the moving part decelerates to stop;
3. Moving part moves back (in positive direction) in creep velocity to detect
Home Abs On
→
Off edge;
4. Once Home Abs switch On
→
Off is detected, start to detect first Ref Pulse
signal coming in;
5. Once the first Ref Pulse signal comes, record the position as mechanical
home position, and decelerate to stop;
6. Move to the configured home position. The mechanical home position
recorded during moving back sequence, plus the home offset configured
for the axis through the Connected Components Workbench software.
Scenario 2: Moving part between Lower Limit and Home switch before homing starts
The homing motion sequence for this scenario is as follows:
1. Moving part moves to its left side (in negative direction);
2. When Lower Limit switch is detected, the moving part decelerates to
stop, or stops immediately, according to Limit Switch Hard Stop
configuration;
3. Moving part moves back (in positive direction) in creep velocity to detect
Home switch On
→
Off edge;
4. Once Home Abs switch On
→
Off is detected, start to detect first Ref Pulse
signal;
5. Once the first Ref Pulse signal comes, record the position as mechanical
home position, and decelerate to stop.
6. Move to the configured home position. The mechanical home position
recorded during moving back sequence, plus the home offset configured
for the axis through the Connected Components Workbench software.
Scenario 3: Moving part on Lower Limit or Home switch before homing starts
The homing motion sequence for this scenario is as follows:
1. Moving part moves to its right side (in positive direction) in creep
velocity to detect Home switch On
→
Off edge;
IMPORTANT
If Home switch or Ref Pulse is not configured as Enabled,
MC_HOME_REF_WITH_ABS (2) homing fails with Error ID: MC_FB_ERR_PARAM.
IMPORTANT
In this case, if Lower limit switch is not configured, or not wired, the homing
motion will fail and moves continuously to the left until the drive or moving
part fails to move.
Содержание Allen-Bradley Micro850
Страница 12: ...12 Rockwell Automation Publication 2080 UM002L EN E November 2021 Preface Notes ...
Страница 36: ...36 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 2 About Your Controller Notes ...
Страница 44: ...44 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 3 Install Your Controller Notes ...
Страница 120: ...120 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 7 Motion Control Notes ...
Страница 156: ...156 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 9 Controller Security Notes ...
Страница 184: ...184 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 10 Using microSD Cards Notes ...
Страница 226: ...226 Rockwell Automation Publication 2080 UM002L EN E November 2021 Appendix C Quickstarts 10 Click Finish to complete ...
Страница 248: ...248 Rockwell Automation Publication 2080 UM002L EN E November 2021 Appendix C Quickstarts Notes ...
Страница 262: ...262 Rockwell Automation Publication 2080 UM002L EN E November 2021 Appendix D User Interrupts Notes ...
Страница 272: ...272 Rockwell Automation Publication 2080 UM002L EN E November 2021 Appendix E Troubleshooting Notes ...