14
It is possible for the paint to jump out in some areas inside the housing after a period of use, due to corrosion caused by liquids,
inadequate fuel types or others not authorized by the manufacturer, etc., In that case it will be necessary to repaint all damaged areas
before a prolonged shutdown period.
Use exclusively "Rocal heatproof spray paint”.
Rocal offers various optional items, contact your local dealer to purchase these items. Some of the items are shown
below:
Item
Code
Description
ECOntrol
C7000
Intelligent combustion control
Regulator
REGULAT-1
Fan speed controller
Log store
C1000
Log store HABIT
E2122-2
BENCH
Ash vaccum cleaner
ASPIRADOR
Below is a table of possible anomalies, their causes and solutions:
PROBLEM
CAUSE
SOLUtION
1. Rejects smoke and / or
insufficient draught
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Dirty flue duct
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply. Simultaneous
operation with other ventilation devices and / or heating
Setting the register
Contact a professional to clean flue duct. If the problem
persists, contact your dealer.
2.
Excessive dirt on glass
Incorrect duct
Inappropriate fuel
Overly closed registers
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
3. Glass bleaching or colour
fading of the plate
Excessive temperature caused by excessive heat in
the combustion chamber
Check the fuel load avoiding overheating
Adjust registers
4. Poor heating
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong position
Use recommended fuel
Adding fuel
Adjust registers
5. Venting smoke and / or
gases from the front, bad
smell
First lighting
Flammable or combustible items in the enclosure or
surrounding walls of the equipment
Crack in the combustion chamber of the equipment
Wait for the polymerization process of the paint to finish;
this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and replace
them.
Check for tightness and if you discover a crack, please
contact your dealer.
6. Excessive draft
Incorrect duct
Combustion control registers in the wrong position
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
7. OPTIONAL COMPLEMENTS
8. PROBLEMS: CAUSE AND SOLUTION
Содержание Habit 73 TC +T
Страница 34: ...1 ANEXO ANNEX ANNEXE ANESSO I mm Habit 73 TC T Habit 93 TC T A 730 930 B 567 592 F 430 430 G 143 143 H 180 180...
Страница 35: ...2 II 1 2 1 2 4 3 5 4 8 6 6 1 7 2...
Страница 36: ...3 III 1 2 3 4 A B...
Страница 37: ...4 III C A 1 A 2 A 3 A 4 A 5...
Страница 38: ...5 III A 6 A 7 A 8 B 1 B 2 B 3...
Страница 39: ...6 III B 4 B 5 B 6 B 7 C 1 C 2...
Страница 40: ...7 III C 4...
Страница 41: ...8 IV D 1 D 2 D 3 D 4 D 5 D 6...
Страница 42: ...9 IV D 7 D 8 D 9 D 10 D 11 D 12...
Страница 43: ...10 IV D 13 D 14 D 15 D 16 D 17 D 18...
Страница 44: ...11 IV D 19 D 20 D 21 D 22...
Страница 47: ......
Страница 48: ......