11
1.1 Technical specifications
Parameter
Model
Habit 73 TC +T
Habit 93 TC +T
Minimum - Maximum draught
11-13 Pa
Fuel consumption
2,8 kg/h
3,56 kg/h
Smoke mass flow rate
10,37 g/s
11,3 g/s
Performance
85%
79,6%
Nominal output
11 kW
12,4 kW
Power range
7,5– 13 kW
8.5 – 14,5 kW
Average CO concentration at 13% of O
2
0,09%
0,085%
Average NO
x
concentration at 13% of O
2
71,5 mg/Nm
3
126 mg/Nm
3
Average OGC concentration at 13% of O
2
36,69 mg/Nm
3
48 mg/Nm
3
Particle concentration
38,69 mg/Nm
3
20,20 mg/Nm
3
Medium draft (trial)
11,3 Pa
12 Pa
Net weight
176 kg
197 kg
Maximum authorized load (fuel)
3.5 kg
5 kg
Reload height
200 mm
200 mm
Logs length
450 mm
600 mm
Minimum flue height
4000 mm
Ø
Flue duct
180 mm
180 mm
Ø
Air inlet
100 mm
Outer fireplace safety distances (frontal)
1000 mm
1000 mm
Outer fireplace safety distances (sides)
1000 mm
1000 mm
Outer fireplace safety distances (back)
600 mm
600 mm
Fireplace room ventilation (entry - exit)
450 cm
2
Electrical wiring connection
Silicone hose 3*wire of 1.5 mm
2
Fan airflow (unit)
135 m
3
/h
Fan output (unit)
20 W
Installed fans
2
4
Minimum safety distance to the air outlets
250 mm
Average temperature of smoke
178º C
261ºC
Type of combustion
INTERMITENT
Flue liner
NOT SHARED
Fuel
NATURAL WOOD
Humidity fuel logs
12-20 % - two years under cover
Certification year
2017
2021
Certificate number
17/14327-852/853 M1
1880-CPR-024-21
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1.
Fireplace’s body.
2.
Heat-resistant spray paint for touch-ups.
3.
Fire grate.
4.
Heat-resistant glove.
5.
Cleaning cloth
6.
Outdoor air intake Kit. (Outdoor air intake connector, support for the connector, tubular seal and screws)
7.
Tool for handling registers and opening door.
8.
Envelope with 3 documents: specifications, installation and operation manual, and Guarantee sheet.
9.
+T
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground.
Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner.
It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter.
The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations
. This Flue liner should not be shared with other devices (see Table 1.1
2. REQUIREMENTS PRIOR TO INSTALLATION
1. SPECIFICATIONS
Содержание Habit 73 TC +T
Страница 34: ...1 ANEXO ANNEX ANNEXE ANESSO I mm Habit 73 TC T Habit 93 TC T A 730 930 B 567 592 F 430 430 G 143 143 H 180 180...
Страница 35: ...2 II 1 2 1 2 4 3 5 4 8 6 6 1 7 2...
Страница 36: ...3 III 1 2 3 4 A B...
Страница 37: ...4 III C A 1 A 2 A 3 A 4 A 5...
Страница 38: ...5 III A 6 A 7 A 8 B 1 B 2 B 3...
Страница 39: ...6 III B 4 B 5 B 6 B 7 C 1 C 2...
Страница 40: ...7 III C 4...
Страница 41: ...8 IV D 1 D 2 D 3 D 4 D 5 D 6...
Страница 42: ...9 IV D 7 D 8 D 9 D 10 D 11 D 12...
Страница 43: ...10 IV D 13 D 14 D 15 D 16 D 17 D 18...
Страница 44: ...11 IV D 19 D 20 D 21 D 22...
Страница 47: ......
Страница 48: ......