![ROC LL1GBQ24-B26CG Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/roc/ll1gbq24-b26cg/ll1gbq24-b26cg_manual-for-use-installation-and-maintenance_1471900031.webp)
Operation mode setting : when the gas boiler is turned on under the non-malfunction
state, softly touch the mode button to switch operation mode, it is divided into three modes:
Sleep mode - after entering the mode, the heating temperat
ure work according
to the original set temperature value of 80%.
Standard Mode - after entering this mode, the variable frequency pump operates
in the standard curve.
Comfort mode - after entering this mode, the variable frequency pump operates
at the highest speed (no frequency conversion).
Clock calibration(if no pressing button and input within 20s, it will automatically save a
nd exit.)
In the OFF mode, long press the [Timing] button for more than 5s to make minutes
calibration; And coordinate [Up / Down ] button to make calibration; then press the
[Timing] button again to make clock calibration; And press the [Timing] button again to
make week calibration; And then press the [Timing] button again or [Power] button to
exit from calibration state. (Calibration Process: Minute-Clock-Week-Exit)
In the on mode, press the [Timing] button to activate the "Day Timing" (connect the power
each time, it will default closing timing function).Press the [Timing]button again to activate
the Week Timing; then press the [Timing] button third times to close the timing function.
(Activation Process: Daily Timing - Weekly Timing - Off)
Day timing setting (or if no input within 20s,it will automatically save and exit)
In Day Timing work mode, long press[Timing] button for more than 5s to make Day Timing
setting (from 00 to 23); First timing period flashes, when pressing [Up ] button, it will allow
the heating during this period, and when pressing [Down
] button ,it will prohibit the
heating during this period. And press again the [Timing] button to select the next period,
cycle operation can set working state of any timing periods freely, and press the [Power]
button to exit the day timing setting state.
Week Timing Settings (built-in orange LED for every week icon)
In the "Week Timing" mode, long press the [Timing] button for more than 5s to set the
"Weektiming"(from Monday to Sunday; then every day from 0 to 23). Just enter week timing
settings, Monday icon is orange flashing indication, the other icon is blue static indication, at
this time press the [Up / Down ] button to select other dates; If some day icon of the week
is orange flashing indication, then press the "Timing" button to enter the day "Day Timing"
setting (specific operation please refer to "Day Timing");Press the [Reset] button to exit
the "Day Timing" setting; then press the [Power] button or no pressing and input within
20s,it will automatically save and exit week timing setting state.
In the state of starting without error, press [mode] button more than 10 seconds to
enter the fan speed automatical matching state (The fan is automatically matched from low
to the high level according to the setting value.It will indicate FL at low speed, and indicate FH
at high speed, automatically save to quit matching state after finishing matching.