40
Supervised parameters
Parameter
Symbol
Notes
Suction pressure
P1
Filter clogging check
Lubricating oil pressure
P3
Maximum and minimum value check
Discharge temperature
T2
Discharge maximum temperature check
Injection oil temperature
T3
Lubricating oil temperature check
Discharge oil temperature
T4
Oil tank temperature control.
Compressor‘s Alarms/Stops
Parameter
Simbolo Allarme
Blocco
Suction pressure
P1
Pressure difference > 35 mbarg
Pressure difference > 45 mbarg
Lubricating oil pressure
P3
-
Pressure > 3 barg
Pressure < 1 barg
Discharge temperature
T2
> setted alarm value
< setted alarm value
> setted maximum value
< setted minimum value
Injection oil temperature
T3
Discharge oil temperature
T4
Modes
Modes
Notes
Modes protection
User
Service
Factory
Measuring unit selection
BAR / PSI
° C / °F
Alarms/Stops display
Displayed alarm codes meaning as per symbols on the instrument
board.
Compressor halt
Compressor stopped when working parameters are outside the
admissible values.
Working hours
Working hours counter.
Working data memorization.
Working data paramenters saved every 15 minutes for the last 30 days.
Alarms/Stop memorization
Every event is memorized with date and hour.
Maintenance
Display of the maintenance operations.
NOTE : For further informations refer to SENTINEL 2 instruction manual.
NOTE : If the compressor is installed with SENTINEL PRO supervision system, please refer tom proper
manual enclosed to the furniture.