RS-Ruby Lite Users’ Manual
7
5 Communication Protocol
RS-Ruby Lite adopts IP/UDP protocol and communicates with computer through gigabit
Ethernet. In this User Guide the length of UDP packet is set up to 1248 byte. The IP address
and port number of RS-Ruby Lite is set in the factory as shown in the Table 2, but can be
changed by user as needed.
Table 2: The IP Address and Port Number Set in the Factory.
IP Address
MSOP Port No.
DIFOP Port No.
RS-Ruby Lite
192.168.1.200
6699
7788
PC
192.168.1.102
The default MAC Address of each RS-Ruby Lite is already set up in the factory with
uniqueness. In order to establishing the communication between a RS-Ruby Lite and a
computer, the IP Address of the computer should be set at the same network segment. For
instance, IP Address is 192.168.1.X (X can be taken by a value from 1~254), subnet mask:
255.255.255.0. If the internet setting of the sensor is unknown, please set the subnet mask as
0.0.0.0, connect the sensor to the computer, and capture UDP packet to get the information of
IP and Port through Wireshark.
The output message from RS-Ruby Lite is called MSOP. The Information of MSOP is shown
as follow:
Table 3: Overview of the MSOP.
Protocol
Abbreviation
Function
Type
Size
Main data Stream Output Protocol
MSOP
Scan Data Output
UDP 1248 byte
Device Information Output Protocol
DIFOP
Device Info Output
UDP 1248 byte
Note: In the following chapters only the valid payload (1248 byte) will be discussed.
Содержание RS-Ruby Lite
Страница 1: ...RS Ruby Lite Users Manual...
Страница 49: ...RS Ruby Lite Users Manual 44 Appendix E Dimension Figure E 1 Dimensions of Ruby...
Страница 52: ...RS Ruby Lite Users Manual 47...
Страница 53: ...RS Ruby Lite Users Manual...
Страница 101: ...RS Ruby Lite Users Manual 44 Appendix E Dimension Figure E 1 Dimensions of Ruby...
Страница 104: ...RS Ruby Lite Users Manual 47...