Message Displayed
Probable Cause/Event
Corrective/User Action
Replace lamp
-
The Operating Lamp is burnt out
-
Confirm the message and replace the
Operating Bulb as soon as possible
Retry elsewhere
-
Calibration failure from interference in the
immediate area
-
Move the RoboMower 10-12 feet (3-4m) from
this spot and attempt calibration again.
Set Country
-
Displayed only on first use.
-
Follow prompts on LCD screen to set country
Set Time
-
Displayed every time the power pack is taken out
of the mower (reset operation)
-
Set real time clock (day and hour)
-
An unknown fault has occurred and user help is
required
-
Manually drive the mower away from this
particular area and restart operation
Start Elsewhere
-
Wheel drive motors have been working under a
severe load
-
Check to insure the mower is not stuck,
allowing the wheels to slip
Thermistors fail
-
Faulty / disconnected Thermistors (overheat
protection)
-
Contact service provider
Time Completed
-
The operating time set for that zone has been
reached
-
Connect to the Power Supply if all mowing has
been completed for the day.
Waiting for signal…
-
RoboMower has stopped the operation in Dock
zone, because there is no signal received from the
Charging Station
-
Check the power to the Charging Station.
-
There is electrical power interruption. There is
no need to do anything – RoboMower will
renew automatically the operation if the power
will come back within an hour from the break.
7.2 Other Operational or Fault Problems
Problem Encountered
Probable Cause/Event
Corrective/User Action
-
Batteries are completely
discharged.
-
Install fresh alkaline C-cell batteries
-
Batteries installed with wrong
polarity position.
-
Verify correct placement of batteries.
Perimeter Switch will not
activate when turned on.
-
Perimeter Switch not installed
vertically and exposed to water/rain.
-
Water/moisture protection of the Perimeter
Switch can only be insured when mounted
vertically. Replace Perimeter Switch.
-
Wire disconnected from switch
-
Confirm wire is plugged in and wire leads are
firmly attached
-
Perimeter wire cut
-
Walk along perimeter, including islands and
obstacles excluded with the perimeter wire and
look for obvious cuts or breaks in the wire.
Repair with RoboMower wire splice
connectors.
'Cut wire’ indicator flashing on
Perimeter Switch
-
Poor connections
-
Check and repair all loose/poor or corroded
connections