66
6) Adjust the tension of the stainless sheet.
[1] While looking through the center opening in the clearance-checking tool, move the stainless sheet on the
loose end in the directions of arrows until the clearance between the top face of the stainless sheet and the
back of the clearance-checking tool falls within the specified range.
[2] When the stainless sheet has been properly positioned, tighten the screws on the loose end to a level that the
stainless sheet no longer moves.
Move the stainless sheet in the directions of
arrows to adjust the tension.
While looking through the center opening, check the clearance between the top face of the stainless sheet and the
back of the clearance-checking tool. (If the clearance is within the specified tolerance range, the tension is
appropriate even when the clearance varies along the entire stroke or between right and left.)
0.5
1.0 mm