![ROBO Cylinder IAI America RCA-SA4C Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/robo-cylinder/iai-america-rca-sa4c/iai-america-rca-sa4c_operating-manual_1470813057.webp)
46
(3) Select the parameter.
(4) Select
the
Axis-specific
parameter tab.
(5) When the axis-specific parameter screen appears, select No. 12, “Home preset.”
(6) Change Axis-specific Parameter No. 12 (home preset).
Add or subtract the difference measured in (2) to/from the value currently entered.
The setting unit is 0.001 mm.
Example: When the measured difference is -1 mm:
Home preset = Current setting – 1000
(7) Write the modified data.
Select the
Axis-specific
parameter tab.
No.12
Select No. 12, “Home preset.”
Click this button to open the parameter edit screen.
S
E
LClick this SEL button to write the data to the controller.