8
Make sure that the connector plate (see picture above) is placed in the right orientation: For horizontal con
-
nections, the marker must be visible from above; for vertical connections, the marker must be visible when
looking from the right side. Fix the connector plate with 4 conical splints, as shown below, and secure it with
the appropriate spring.
Continue for every connection between Fixtures.
4.2.2 Hanging a StageQube324 array from a truss
The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1
hour without any harming deformation.
the installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
this secondary safety attachment must be constructed in a way that no part of the installation can fall down if
the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert
before taking into operation for the first time and after changes before taking into operation another time. The
operator has to make sure that safety-relating and machine-technical installations are approved by an expert
after every fourth year in the course of an acceptance test.
the operator has to make sure that safety-relating and machine-technical installations are approved by a skilled
person once a year.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all installation
material and the projector. If you lack these qualifications, do not attempt the installation yourself, but instead use
a professional structural rigger. Improper installation can result in bodily injury and or damage to property.
The fixture has to be installed out of the reach of people.
If the fixture shall be lowered from the ceiling or high joists, professional trussing systems have to be used. The
fixture must never be fixed swinging freely in the room.
Caution: Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of
a possible installation, do not install the fixture!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the fixture’s
weight.