6
3. Installation
Fixtures must be installed by a qualified electrician in accordance with all
national and local electrical and construction codes and regulatio
n.
3.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin miniPointe is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz
AC power source from 100-240 Volts.
This fixture must be earthed. To use the fixture, a plug must be fixed.
The correct assembly of a sufficient plug may be done by professional persons only.
The conductors in the cable are marked by the following table.
Core (EU)
Core (US)
Connection Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Green /Yellow Green
Earth
Design of the Robin miniPointe allows to connect several fixtures to AC mains power in one interconnected
daisy chain using power input and throughput connectors. Needed daisy chain cords are stated in the chapter
“Technical specifications “
The max. number of connected fixtures depends on the AC mains power voltage and fixture version:
EU version (CE)
US version (cETLus)
15 fixtures at power supply= 230V
9 fixtures at power supply= 230V
13 fixtures at power supply= 208V
7 fixtures at power supply= 208V
7 fixtures at power supply= 120V
5 fixtures at power supply= 120V
Do not overload the supply line and the connecting leads.
Wiring and connection work must be carried out by qualified staff!