20
7.2 Info (Fixture information)
PO Time
(Power On Time)
-
Select the menu to read the number of fixture operation hours.
Total
- the item shows the total number of the operation hours since the ROBIN iBeam 250
has been fabricated.
Reset
- the item shows the number of operation hours that the ROBIN iBeam 250 has
been powered on since the counter was last reset.
In order to reset this counter to 0, press and hold both [NEXT] and [PREV] buttons and
the [Enter] button at the same time.
LOTi
(LEDs On Time)
-
Select the menu item to read the number of operation hours of individual LEDs (Red,
Green, Blue, White).
R LOT.
- Red LEDs on time.
G LOT.
- Green LEDs on time.
B LOT.
- Blue LEDs on time.
W LOT.
- White LEDs on time.
DMX In (DMX readout)
-
The menu is used to read DMX values of each channel received by the fixture.
Hea. Tmp
(Head Temperature)
- the menu shows temperatures on the LED module.
Current
- a current temperature of the LED module.
Highest
- a maximum temperature of the the LED module since the fixture has been fabricated.
High Res (High Resetable)
- a maximum temperature of the the LED module since the counter
was last reset.
In order to reset this counter, press and hold both [NEXT] and [PREV] buttons and
the [Enter] button at the same time.
IP Addr.
(IP Address)
- the menu allows you to read four decimal numbers of IP address.
MAC Addr.
(MAC Address)
- the menu allows you to read six decimal numbers of MAC address.
RDM UID
- the menu allows you to read RDM UID of the fixture.
Sw Ver
(
Software versions) -
Select this item to read the software version of the fixture modules.
IC-1
- Display processor
IC-2
- EEprom
IC-3
- Pan/Tilt control processor.
IC-4
- LED control processor.
IC-5
- LED control processor.
WL
- Wireless DMX module.
7.3 Pers (Personality)
DMX Pres (DMX Preset)
- use the menu to select desired channel mode.
Mode 1
- 22 control channels
Mode 2
- 16 control channels
Mode 3
- 24 control channels (default)
DMX In
(
DMX input)
- use the menu to select mode of DMX signal receiving.
Wired
- DMX signal is received by means of the standard DMX cable.
Wireless
- DMX signal is received by means on inbuilt wireless DMX module.
Ethernet
- DMX signal is received by means of ETHERNET cable.
Ethernet
- the menu allows you to set fixture for Ethernet operation.
Eth Mode (Ethernet Mode)
- the menu item allows you to select desired protocol:
ArtNet
sACN
gMA
I
gMA
II
ArtNet
- use the menu item to select desired universe for ArtNet (Uni), range 0-255
sACN
- use the menu item to select desired universe for sACN (Uni), range 1-63999
MANet
- use the menu item to select desired universe (Uni) for MANet, range 1-256 and
ID session (sID), range 1-32.