24
Calibration of the pan/tilt/zoom via the control board
1. Disconnect DMX controller from the fixture and enter the "Cal Mech" menu.
2. Use [PREVIOUS] and [NEXT] buttons to find "Pan C" and touch [ENTER] button.
3. Set desired value and save it by touching [ENTER] button.
4. Repeat steps 2 and 3 for "Tilt C" and "Zoom C".
5. After calibrating all effects, find item "Store" and press [ENTER] button. to save all adjusted values and reset
the fixture.
Calibration protocol:
Effect
Mode 1
Mode 2
Mode 3
Pan-fine adjustment
channel 23
channel 17
channel 25
Tilt - fine adjustment
channel 24
channel 18
channel 26
Zoom -fine adjustment
channel 25
channel 19
channel 27
Cal. Load
- the item loads default (factory) calibration values.
Sw Upd (Software update)
- the menu item allows you to update software in the fixture via either serial or
USB port of PC.
The following items are required in order to update software:
- PC running Windows or Linux or macOS
- DSU file
- Flash cable RS232/DMX, P/N13050624 (if you want to use a serial port of PC)
- Robe Universal Interface or Robe Universal interface WTX (if you want to use an USB port of PC)
To update software in the fixture:
1. DSU file is available from Robe web site at WWW.robe.cz.
File with extension zip is intended for Windows (used and tested from XP to W10 on 32/64bit systems).
File with extension tbz is intended for Linux (used and tested on Debian and Ubuntu 32/64bit).
File with extension dmg is intended for
macOS (used and tested on OSX up to Sierra) XQuartz required,
install it from https://www.xquartz.org/
Save the download file to a folder on your computer.
In case that you use windows, extract files in the zip file (e.g. DSU_RobiniBeam250_18041738.zip)
2. Disconnect the fixture from DMX controller.
3. If you use the flash cable RS232/DMX, connect a serial port of your computer with DMX input of the fixture
by means of the cable.
If you use the Robe Universal Interface, connect a USB port of your computer with the Robe Universal Interface
by means of the USB cable and DMX input of the fixture with the DMX output of the Robe Universal Interface
via a DMX cable.
4. Switch the fixture to the update mode (Special --> SW Upd).
Note: If you do not want to continue in the software update, you have to switch off and on the fixture
to escape from the updating mode.
We recommend to cancel all running programs on your computer before starting the software update.
5. Double-click the software uploader file (e.g. DSU_RobiniBeam250_18041738.exe) in
the extracted files. The Software Uploader program will start running.
6. Select correct "COM " number if you use a
Flash cable RS232/DMX
or select "Robe Universal Interface 1 "
Содержание ROBIN iBeam 250
Страница 1: ...1 Version 1 3 QR code for user manual ...
Страница 15: ...15 Pan tilt positions ...
Страница 32: ...32 12 Photometric diagrams Min zoom ...
Страница 33: ...33 Max zoom ...