10
Ethernet
/
DMX
operation
Only
first
fixture
is
connected
to
Ethernet
and
the
rest
of
fixtures
make
up
a
standard
DMX
link.
The
option
“Ethernet/DMX”
has
to
be
selected
from
the
“Set
Ethernet
Mode”
menu
on
the
first
fixture
(connected
to
the
network).
Next
fixtures
have
standard
DMX
addressing.
Caution:
At
the
last
fixture,
the
DMX
clink
has
to
be
terminated
with
a
terminator.
Solder
a
120
Ohm
resistor
between
Signal
(–)
and
Signal
(+)
into
a
XLR
‐
plug
and
connect
it
to
the
DMX
output
of
the
last
fixture.
Example: