background image

REDWash

 

3•192

 

 

3

 

 

FOR

 

YOUR

 

OWN

 

SAFETY,

 

PLEASE

 

READ

 

THIS

 

USER

 

MANUAL

 

CAREFULLY

 

BEFORE

 

POWERING

 

OR

 

INSTALLING

 

YOUR

 

REDWash

 

3

192

 

!

 

Save

 

it

 

for

 

future

 

reference.

 

 

This

 

device

 

has

 

left

 

our

 

premises

 

in

 

absolutely

 

perfect

 

condition.

 

In

 

order

 

to

 

maintain

 

this

 

condition

 

and

 

to

 

ensure

 

a

 

safe

 

operation,

 

it

 

is

 

absolutely

 

necessary

 

for

 

the

 

user

 

to

 

follow

 

the

 

safety

 

instructions

 

and

 

warning

 

notes

 

written

 

in

 

this

 

manual.

 

 

The

 

manufacturer

 

will

 

not

 

accept

 

liability

 

for

 

any

 

resulting

 

damages

 

caused

 

by

 

the

 

non

observance

 

of

 

this

 

manual

 

or

 

any

 

unauthorized

 

modification

 

to

 

the

 

device.

 

 

Please

 

consider

 

that

 

damages

 

caused

 

by

 

manual

 

modifications

 

to

 

the

 

device

 

are

 

not

 

subject

 

to

 

warranty.

 

 

The

 

REDWash

 

3

192

 

was

 

designed

 

for

 

indoor

 

use

 

and

 

it

 

is

 

intended

 

for

 

professional

 

application

 

only.It

 

is

 

not

 

for

 

household

 

use.

 

 

1.

 

Safety

 

instructions

 

 

DANGEROUS

 

VOLTAGE

 

CONSTITUTING

 

A

 

RISK

 

OF

 

ELECTRIC

 

SHOCK

 

IS

 

PRESENT

 

WITHIN

 

THIS

 

UNIT!

 

 

Make

 

sure

 

that

 

the

 

available

 

voltage

 

is

 

not

 

higher

 

than

 

stated

 

on

 

the

 

rear

 

panel

 

of

 

the

 

fixture.

 

This

 

fixture

 

should

 

be

 

operated

 

only

 

from

 

the

 

type

 

of

 

power

 

source

 

indicated

 

on

 

the

 

marking

 

label.

 

If

 

you

 

are

 

not

 

sure

 

of

 

the

 

type

 

of

 

power

 

supplied,

 

consult

 

your

 

authorized

 

distributor

 

or

 

local

 

power

 

company.

 

 

Always

 

disconnect

 

the

 

fixture

 

from

 

AC

 

power

 

before

 

cleaning,

 

removing

 

or

 

installing

 

the

  

fuses,

 

or

 

any

 

part.

 

 

Make

 

sure

 

that

 

the

 

power

 

switch

 

is

 

set

 

to

 

off

position

 

before

 

you

 

connect

 

the

 

fixture

 

to

 

the

 

mains.

 

The

 

power

 

plug

 

has

 

to

 

be

 

accessible

 

after

 

installing

 

the

 

fixture.

 

Do

 

not

 

overload

 

wall

 

outlets

 

and

 

extension

 

cords

 

as

 

this

 

can

 

result

 

in

 

fire

 

or

 

electric

 

shock.

  

 

Do

 

not

 

allow

 

anything

 

to

 

rest

 

on

 

the

 

power

 

cord.

 

Do

 

not

 

locate

 

this

 

fixture

 

where

 

the

 

cord

 

may

 

be

 

damaged

 

by

 

persons

 

walking

 

on

 

it.

 

 

Make

 

sure

 

that

 

the

 

power

 

cord

 

is

 

never

 

crimped

 

or

 

damaged

 

by

 

sharp

 

edges.

 

Check

 

the

 

fixture

 

and

 

the

 

power

 

cord

 

from

 

time

 

to

 

time.

 

 

Refer

 

servicing

 

to

 

qualified

 

service

 

personnel.

 

 

This

 

fixture

 

falls

 

under

 

protection

 

class

 

I.

 

Therefore

 

this

 

fixture

 

has

 

to

 

be

 

connected

 

to

 

a

 

mains

 

socket

 

outlet

 

with

 

a

 

protective

  

earthing

 

connection

.

 

 

Do

 

not

 

connect

 

this

 

fixture

  

to

 

a

 

dimmer

 

pack.

 

 

 

Do

 

not

 

look

 

straight

 

at

 

the

 

fixture

 

front

 

LEDs

 

during

 

operation.

 

The

 

intense

 

light

 

beam

 

may

 

damage

 

your

 

eyes.

 

 

 

If

 

the

 

fixture

 

has

 

been

 

exposed

 

to

 

drastic

 

temperature

 

fluctuation

 

(e.g.

 

after

 

transportation),

 

do

 

not

 

switch

 

it

 

on

 

immediately.

 

The

 

arising

 

condensation

 

water

 

might

 

damage

 

your

 

device.

 

Leave

 

the

 

device

 

switched

 

off

 

until

 

it

 

has

 

reached

 

room

 

temperature.

 

Содержание redwash 3-192

Страница 1: ...Version 1 4 ...

Страница 2: ...Wash 3 192 DMX protocol 11 5 Control menu map 14 6 Fixture menu 16 6 1 Fixture Address 16 6 2 Fixture information 17 6 3 Personality 18 6 4 Test sequences 19 6 5 Manual mode 19 6 6 Stand alone setting 19 6 7 Reset function 20 6 8 Special Functions 20 7 Power down mode 22 8 RDM 23 9 Error and information messages 24 10 Technical specifications 25 11 Cleaning and maintenance 27 11 1 Replacing the ma...

Страница 3: ...e of the type of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Make sure that the power switch is set to off position before you connect the fixture to the mains The power plug has to be accessible after installing the fixture Do not overload wall outlets and extensi...

Страница 4: ...ting this fixture Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Do not block the front objective LEDs with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture to cool approximately 20 minutes prior to manipulate with it Operate the fixture only after having familiarized with...

Страница 5: ...t panel 8 Pan lock 9 Holder Front panel of fixture base 1 LCD display 2 RNS rotary wheel 3 Escape button 4 Enter button Rear panel of the fixture base 1 Power switch 2 Main fuse 3 Power cord 4 DMX output 5 pin XLR 5 DMX input 5 pin XLR 6 DMX output 3 pin XLR 7 DMX input 3 pin XLR 8 Ethernet input RJ 45 ...

Страница 6: ...orking places and other endangered areas is forbidden For overhead use always install a safety rope that can hold at least 10 times the weight of the fixture You must only use safety ropes with screw on carbines Pull the safety rope through the two apertures on the bottom of the base and over the trussing system etc Insert the end in the carbine and tighten the fixation screw Rigging the fixture v...

Страница 7: ... that the lens module locks 2 are properly locked 6 Shift the security lock 1 to the locked position red mark to secure the lens module in the placing Ensure the security lock is in the locked position RED mark before starting the fixture operation t is possible to install a plastic film to the glass holder module in order to get frost light 1 Uninstall the 25 lens array module 1 as described abov...

Страница 8: ...troller with the fixture or one fixture with another Wiring of the XLR connectors DMX output DMX input XLR mounting sockets rear view XLR mounting plugs rear view 1 Shield 2 Signal 3 Signal 4 Not connected 5 Not connected To build a DMX chain 1 Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain 2 Connect the DMX output of the first fixture in...

Страница 9: ...wisted wire pairs and standard RJ 45 plugs in order to connect the fixture to the network RJ 45 socket front view RJ 45 plug front view 1 TD 5 Not connected 2 TD 6 RX 3 RX 7 Not connected 4 Not connected 8 Not connected Patch cables that connect fixtures to the hubs or LAN sockets are wired 1 1 that is pins with the same numbers are connected together 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 If only the fi...

Страница 10: ...et DMX has to be selected from the Set Ethernet Mode menu on the first fixture connected to the network Next fixtures have standard DMX addressing Caution At the last fixture the DMX clink has to be terminated with a terminator Solder a 120 Ohm resistor between Signal and Signal into a XLR plug and connect it to the DMX output of the last fixture Example ...

Страница 11: ...le small large Figure of triangle small large Figure of five pointed star small large Figure of cross small large proportional proportional proportional proportional proportional proportional proportional 7 7 7 0 1 127 128 129 130 255 Pan Tilt Macro Speed Set pan tilt speed channel 5 at 0 DMX No macro generation Macro generation fast slow forwards No macro generation Macro generation slow fast bac...

Страница 12: ... saturation control 0 100 proportional 15 11 19 0 255 Blue LEDs Array 2 Blue LEDs saturation control 0 100 proportional 16 12 20 0 255 White LEDs Array 2 White LEDs saturation control 0 100 Proportional 17 13 21 0 255 Red LEDs Array 3 Red LEDs saturation control 0 100 proportional 18 14 22 0 255 Green LEDs Array 3 Green LEDs saturation control 0 100 proportional 19 15 23 0 255 Blue LEDs 3 Array 3 ...

Страница 13: ...5 Macro 26 Macro 27 Macro 28 Macro 29 Macro 30 Macro 31 step step step step step step step step step step step step step step step step step step step step step step step step step 26 22 14 10 0 31 32 63 64 95 96 127 128 143 144 159 160 191 192 223 224 255 Shutter Strobe Shutter closed Shutter open Strobe effect slow fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequenc...

Страница 14: ...ime Fixture temperature Current Head Temp LEDs Temp Max Nonresetable Head Temp LEDs Temp Maximum Resettable Head Temp LEDS Temp DMX Values Pan 0 255 Dimmer Fine 0 255 Software Version IC1 B IC2 B IC1 H IC1 DS IC2 DS Product Ids Mac Adr RDM UID Personality User Mode User A Settings User B Settings User C Settings DMX Preset Mode 1 Ch 1 Pan Ch 28 Dimmer fine Set Active Mode 2 Ch 1 Pan Ch 24 Dimmer f...

Страница 15: ...un Test Program Mode 2 Manual Mode Preset Effect Control Pan Position 1 7 Dimmer Position 1 6 Manual Effect Control Pan 0 255 Dimmer Fine 0 255 Stand alone Setting Music Trigger On Off Preset Playback Disabled Test program Program 1 Program 3 Playing Program Test Program in Loop Program 1 in Loop Program 3 in Loop Editing Program Program 1 Edit Steps Step 1 Pan 0 255 Program 3 Step 99 Dimmer Fine ...

Страница 16: ...hernet Mode use the menu to set an Ethernet functional mode Disable Ethernet Disables an Ethernet operation Ethernet control data is received to the Ethernet input of the fixture RJ45 socket Each of fixtures has to be connected to Ethernet Ethernet DMX control data is received to the Ethernet input of the fixture goes throw the fixture to its DMX output fixture works as an Ethernet DMX converter I...

Страница 17: ...od is 10 hours max is 300 hours Elapsed Time the option allows you to read the time which remains to cleaning air filters The time period is set in the menu mentioned above Expired time period is signalized by a negative mark at the time value and a warning icon triangle on the display with the following message Clean Air Filters Clean the filters and reset this menu item by pressing the ENTER but...

Страница 18: ... to turn it off automatically 2 minutes after last pressing any button on the control panel Display Intensity select this function to adjust the display intensity 1 min 10 max Display Backlight select this function to adjust the display backlight 1 min 10 max Display Turned select this function to turn the display by 180 Blackout d M C This function enables to close a light output while the moving...

Страница 19: ...lour the Green Balance 9 Repeat steps 6 7 for this channel 10 Use the RNS rotary wheel to select the last colour the Blue balance and repeat steps 6 7 for this colour LEDs Output Power The menu allows to choose 2 different operating modes for fixture s LEDs Maximum Max light output Maximum light output Note in this mode the total lumen maintenance is 70 at 10 000 hours Economical The light output ...

Страница 20: ...the Stand alone setting menu and press the ENTER button 2 Use the RNS rotary wheel to select the Editing Program menu and press the ENTER button 3 Select the program you want to edit Program 1 Program 3 and press the ENTER button 4 Select the Edit Steps menu and press ENTER 5 Select the desired program step Step 01 Step 99 and press the ENTER button 6 Now you can edit DMX values for selected items...

Страница 21: ...e_Uploader on your hard disk and download the software to it 3 Unpack the program from the archive If the Robe fixture is produced in both magnetic and electronic ballast version name of DMX Software Uploader is the same for both versions II Fixture software updating 1 Determine which of your ports is available on your PC and connect it with the DMX input of the fixture if you using the flash cabl...

Страница 22: ...e finishing software upload After switching again the fixture on the fixture is still in the updating mode and the display is dark Restart the Software Uploader program and repeat software update from your PC 7 Power down mode This mode omits fixture reset after switching it on and reduces the power of motors The Power down mode is useful in special cases e g if the fixture is in a flight case and...

Страница 23: ...ows a console or dedicated RDM controller to send commands to and receive messages from specific moving lights RDM allows explicit commands to be sent to a device and responses to be received from it The list of commands for the REDWash 3 192 is the following Parameter ID Discovery command SET command GET command DISC_UNIQUE_BRANCH DISC_MUTE DISC_UN_MUTE DEVICE_INFO SUPPORTED_PARAMETERS SOFTWARE_V...

Страница 24: ...pping motor is defective or its driving IC on the PCB The yoke is not located in the default position after the reset of the fixture Tilt Error 1 Tilt Error 2 This message will appear after the reset of the fixture if the head s magnetic indexing circuit malfunctions sensor failed or magnet is missing or the stepping motor is defective or its driving IC on the PCB The head is not located in the de...

Страница 25: ... graphic LCD display and ROBE navigation system Control USITT DMX 512 RDM support Art Net protocol ready for ACN DMX protocol modes 5 8 16 24 or 28 control channels Control options DMX Auto trigger Audio trigger Operations modes DMX Stand alone Manual control of all effects via control panel Strobe Strobe effect with variable speed max 20 flashes per sec Pre programmed random strobe pulse effects ...

Страница 26: ...power all LEDs at max intensity ambient temperature 20 C 68 F Dimensions mm Weight 22 kg 48 5lbs Included items 1 x REDWash 3 192 1 x Lens module 25 No 99012301 installed in the fixture 1 x glass holder for frost filters No 10980055 1 x grid module No 17040456 2 x Mounting bracket Omega CL assembled 1 x User manual Optional accessories Flash cable RS232 DMX No 13050624 Remote control IR No 1305041...

Страница 27: ...tenance and service operations are only to be carried out by authorized distributors 11 1 Replacing the main fuse Only replace the fuse by the one of the same type and rating To replace the fuse 1 Disconnect the fixture from mains 2 Unscrew the fuse holder on the rear panel of the base with a fitting screwdriver from the housing anti clockwise 3 Remove the old fuse from the fuse holder 4 Install t...

Отзывы: