![Robe DT Series Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/robe/dt-series/dt-series_user-manual_1468877077.webp)
RMS-Robe Media Server
77
4.
Press the [ENTER] and the screen where the size of the ArcDots matrix has to be defined will appear.
5.
After setting matrix width and height, go to the menu “
Config PM Outputs
”. If DMX is used for connection
between the Robe Media Server and ArcPixPower set, the number of ArcDots connected to DMX 1 (DMX
2) output.
Note:
DMX 1:
3-pin XLR
DMX 2 :
5-pin XLR
If the ArtNet is used, select the option “
Num. Dots On Artnet
“ and the following screen will appear.
6.
Run the “
Scan Network For ArcPowers
“ to find all ArcPixPowers. List of IP addresses of found
ArcPixPowers will be displayed above in the item “ Create New Node”.
In case that you need to create a new node on the Artnet (option “
Scan Network For ArcPowers
“ finds
ArcPixPower drivers only), use the option “
Create New Node
“ to edit its IP address, ArtNet Universe and
number of dots connected to the node.
Содержание DT Series