Installation and Commissioning
................................................................................................................................................................................................
................................................................................................................................................................................................
Manual TRZ 04 · EN04 · February, 1st 2017
24
1.14 I
nstalling the device in the pipeline
The units of RMG are equipped with flanges.
The flange connections for the connected pipes must comply with the connecting
dimensions of the flanges of the unit
:
•
ANSI-
pressure levels
:
Flange in accordance with
ASME B 16.5.
•
DIN-
pressure levels
:
Flange in accordance with
DIN EN 1092.
Danger
Gas leakage for the wrong gaskets
If wrong flange gaskets are used for connecting turbine gas meters, gas may
flow through leaks resulting in an explosive gas mixture.
Poisoning and explosion hazard !!
In addition, the stress of the flange is increased inadmissible when tightening
the bolts.
Make sure that no flange gaskets are protruding into the pipe.
Pay attention to a save mounting / hanging-up of the TRZ04 during assembly to
avoid the risk of bruising. Avoid to have your fingers (or other body parts)
between any openings and gaps that are moved together when tightening the
flanges !!
Notice
Malfunction due to incorrect gaskets
When wrong flange gaskets are used for turbine meters, which protrude into
the pipe, the measurement accuracy may be affected.
Make sure that the flange gaskets on the sealing surfaces are not protrude
into the pipe.
The stability of the flange connection for gaskets and bolts with certain material properties
(see chapter 2.2.3
Seals
and chapter 2.2.4
Screws
) was proved to AD2000 regulations.
Other screw / flange - variants were not verified.
Introduction