![background image](http://html1.mh-extra.com/html/rmg/erz2000-ng/erz2000-ng_operating-manual_1467424114.webp)
3 Electrical connections
Manual ERZ 2000-NG · EN07 · 2019, May 13th
104
X 4
Terminal 1
Current output 1 +
Terminal 2
Current output 1 -
Terminal 3
Current output 2 +
Terminal 4
Current output 2 -
Terminal 5
Current output 3 +
Terminal 6
Current output 3 -
Terminal 7
Current output 4 +
Terminal 8
Current output 4 -
Terminal 9
Input for Vo with external separator stage +
Terminal 10
Input for Vo with external separator stage -
X 5
Terminal 1 Curr. input1, active or passive, pol. see connection examples
Terminal 2 Curr. input 1, active or passive, pol. see connection examples
Terminal 3 Curr. input 2, active or passive, pol. see connection examples
Terminal 4 Curr. input 2, active or passive, pol. see connection examples
Terminal 5 Curr. input 3, active or passive, pol. see connection examples
Terminal 6 Curr. input 3, active or passive, pol. see connection examples
Terminal 7 PT 100/500/1000 # 1 +
standard connection
Terminal 8 PT 100/500/1000 # 1 sense +
standard connection
Terminal 9 PT 100/500/1000 # 1 sense -
standard connection
Terminal 10 PT 100/500/1000 # 1 supply - -
standard connection
X 6
Terminal 1 Curr.input 4, active or passive, pol. (see connection examples)
Terminal 2 Curr.input 4, active or passive, pol. (see connection examples)
Terminal 3 Curr.input 5, active or passive, pol. (see connection examples)
Terminal 4 Curr.input 5, active or passive, pol. (see connection examples)
Terminal 5 Curr.input 6, active or passive, pol. (see connection examples)
Terminal 6 Curr.input 6, active or passive, pol. (see connection examples)
Terminal 7 Curr.input 7, pol. opposite 1-6, or reserve PT 100*
Terminal 8 Curr.input 7, pol. opposite 1-6, or reserve PT 100*
Terminal 9 Curr.input 8, pol. opposite 1-6, or reserve PT 100*
Terminal 10 Curr.input 8, pol. opposite 1-6, or reserve PT 100*
Note
* X6: Whether the terminals are reserve PT 100 or current input 7 and 8 can be
determined by the hardware coding (jumper).
Factory setting: Current input 7 and 8.
Содержание ERZ2000-NG
Страница 10: ......
Страница 43: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 33 Figure 17 Display of the ERZ2000 NG in the browser...
Страница 68: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 58 Figure 44 Menu LA Overview...
Страница 69: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 59 Figure 45 Menu LB Totalizer BM1...
Страница 77: ...2 Introduction Manual ERZ 2000 NG EN07 2019 May 13th 67 Figure 51 Overview System sub menu...
Страница 109: ...3 Electrical connections Manual ERZ 2000 NG EN07 2019 May 13th 99 Figure 81 Menu EH Module assembly...
Страница 111: ...3 Electrical connections Manual ERZ 2000 NG EN07 2019 May 13th 101 Figure 83 Menu EI Configuration...
Страница 241: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 231 Figure 167 Interface module C34...
Страница 261: ...6 Flow meters Manual ERZ 2000 NG EN07 2019 May 13th 251 6 5 2 AP diff pressure Figure 184 Menu AP differential pressure...
Страница 340: ...8 Overview Coordinates Manual ERZ 2000 NG EN07 2019 May 13th 330 8 5 6 TSV export...
Страница 345: ...9 Faults Manual ERZ 2000 NG EN07 2019 May 13th 335 9 1 2 JB Message register Figure 249 Menu JB Message register...
Страница 347: ...9 Faults Manual ERZ 2000 NG EN07 2019 May 13th 337 9 1 4 JD Debugging Figure 251 Menu JD Debugging...
Страница 448: ...Appendix Manual ERZ 2000 NG EN07 2019 May 13th 438 K 18 T Trend TA Trend block See chapter 2 5 8 Trend...
Страница 453: ...Certificates Manual ERZ 2000 NG EN07 2019 May 13th 443...