To configure the sample rate on the device:
1. Enter the
CLOCK
section (
2. Use the button next to the current sample rate. Two blue arrows will appear to indicate that the
encoder can now be used to change the rate.
3. Rotate the encoder until the preferred sample rate is shown.
4. Push the encoder again to activate the setting.
To configure the device sample rate on the web remote:
1. In the clock panel, click the first icon containing the current sampling rate.
2. Select the new sampling rate.
10.3.4. Effects of Sample Rate Changes on Existing Routing
The 12Mic-D saves one routing table per preset, regardless of sample rate. A change of sample rate or
MADI frame mode can reduce the number of input and output channels available for routing. This does
not alter the routing table. Any existing routing is hidden until another change of sample rate re-enables
the channels.
Example:
A routing is created at 96 kHz with 32 channels, sending the MADI coaxial Input 1-32 to optical MADI
Output 1-32. If the sample rate is now changed to 176.4 kHz and the 56 Ch frame is activated, only the
RME 12Mic-D User’s Guide
10.3. Sample Rates Overview |
76