Connection and programming examples
30
SYCON
3000 C
Delete key at IN 2
Function:
If a relay has been permanently activated, it can be deactivated again at the instrument or by means of a
remote switch (external delete key).
Programming:
3.2 = Rest
= Function "Reset relay/horn"
3.3 = Rest |
= Reset of the relay when contact closed
4.3 = 1s
= Delay time for the reset of the relay = 1 second
Recorder at RC 1
Function:
The recorder serves to log the activities of the instrument. Different current values are allocated to the differ-
ent activities.
Programming:
8.1
= 4
mA = Analysis
active
8 mA = Analysis: soft water
12 mA = Analysis: hard water
16 mA = Refill indicator
20 mA = Fault in the measurement
Recorder at RC 2
Function:
The recorder serves to log the measured values of the instrument. Initial and final values are determined in
accordance with the chosen measurement range and the indicator type in programme step 1.1.
Programming:
8.2
= 0
mA = 0
mg/l
CaCO
3
20 mA = 160 mg/l CaCO
3