Control LZ 60 "b" (examples)
Hall sensor evaluation / signal paths
•
Active output stage with 1220R output resistance.
•
Hall sensor supply voltage 5 V...24 V
•
Current consumption: Depends on the power supply and the load of the outputs, max. 50 mA
•
Output current: in and out internally limited via 1220 Ohm.
•
Frequency of the hall sensor impulses at 24 V max. 100 Hz
•
Frequency of the hall sensor impulses at 36 V max. 150 Hz