7. Life phases
51
D
e
u
ts
ch
E
n
g
li
sh
7.4 Electrical connecting options
Different electric connecting options are available. They must be accordingly specified when
ordering. Wiring is carried out by the customer.
7.4.1 Electrical connection "a"
For connection (2.5 m) to an RK transformer control or an
external fixed source of voltage with DIN loudspeaker
connector and connection cable guided out. A connector for
limit switch internally wired.
Motor direction of rotation
Upper limit switch
Lower limit switch
Wiring diagram
M
Option
Direction
1
+
-
Extend
2
-
+