Chimney must be dimensioned in a correct way ac-
cording to the type of thermostove it is connect-
ed with, minding the environmental and general
conditions of the place in which it is placed. The
section of the chimney must permit the flow of
the fumes produced by the thermostove without
difficulties, but it must not be too big otherwise
the chimney will experience problems in heating
itself and this may generate problems like weak
draft and condensation. In table 1 it is indicated
the recommended diameter for the flue according
to the height of the chimney. The height of the
chimney must be enough to insure the draft nec-
essary. Bigger is the height of the chimney, bigger
is the draft; if the chimney is lower than 4 metres,
the correct working of the thermostove is not in-
sured. The chimney must not have tortuous parts,
horizontal parts or counterslope parts; the number
of bends must be reduced to minimum. In picture 6
you can see some examples of good and bad chim-
ney connection.
2.4
DIMENSIONS AND CORRECT FORMS OF CHIMNEY
Picture 6 - Samples of correct and incorrect chimney connection
NO
H
Picture 7 - H dimension for the sizing
of the flue
Table 1 - Indications for the dimension of the chimney according
to its height.
ø entrance
ø flue H < 4m
ø flue 4m < H < 6m
ø flue H > 6m
Necessary depression
150 mm
Draught not guaranteed
180 mm
160 mm
13 Pa
Model
T Series
YES
Содержание T Art Basic
Страница 1: ...Istruzioni d uso Gebrauchsanweisung Instructions Manuel d utilisation ...
Страница 2: ......
Страница 37: ...ITALIANO 35 ...
Страница 71: ...DEUTSCH 69 ...
Страница 105: ...ENGLISH 103 ...
Страница 139: ...FRANÇAIS 137 ...
Страница 140: ...138 ...
Страница 141: ...139 ...
Страница 142: ...140 ...
Страница 143: ...FRANÇAIS 141 ...