ENGLISH
81
The thermostoves are endowed with boiler to
use the heating produced by the device through
a system with fluid vector for heating and for the
production of hot water. The system must be de-
signed according to UNI 10412-2:2006 law by a
qualified thermal technician and must be installed
by experienced people according to existing laws
in particular to UNI 10683:2005 law. The ther-
mostoves are endowed with all the necessary pre-
dispositions for a correct installation, every exter-
nal component (as pumps, valves, acoustic alarms,
pressure switches) must be obtained by third parts
according to the specifies of designer and installer.
3.1
GENERAL NOTES
3.2
CONNECTIONS TO THE HEATING SYSTEM
HEATING SYSTEM
3
Picture 13 – Placement of the boiler connections.
245
490
134
134
252
701
767
829 1187
90
90
5
6
4
2
1
3
4
CAPTION
1) Connection detector of auxiliary
thermostat (optional) Ø ½” F
2) Going connection Ø 1”¼ F
3) Bulb for thermal discharge
detector (optional) Ø ½” F
4) Connection for thermal discharge
circuit (optional) Ø ½” M
5) Return connection Ø 1”¼ F
6) Connection discharge Ø ½” F