SteelCentral™ NetExpress Appliance Installation Guide
31
Mechanical and electrical specifications
Specifications
Amber
–
Blinking - Major alarm. Non-fatal failure. The hardware platform is still operating in a degraded condition,
but is likely to soon halt.
–
Continuously on - Critical alarm. The hardware platform has failed or shut down.
Disk fault indicators
Each disk drive has an amber fault indicator. It is necessary to remove the bezel to see the fault indicators. Pull the left
end of the bezel to remove it. To reinstall it, hook the right end on to the chassis first.
The fault indicator on a disk drive lights amber continuously if the disk has failed of if it has not yet been added to the
RAID configuration.
Mechanical and electrical specifications
The NetExpress requires one rack unit (1U).
Regulatory compliance code:
1UACA
Product model:
SCNE-00470
Dimensions
Height: 43.2 mm, 1.7 in.
Width 438 mm, 17.2 in.
Depth: 640.4 mm, 25.2 in.
Weight:
13.2 kg, 29 lbs.
Power:
90V-132V, 47 - 63 Hz
180V-264V, 47 - 63 Hz
135W
Содержание SteelCentral NetExpress
Страница 1: ...SteelCentral NetExpress Appliance Installation Guide Model SCNE 00470 Version 10 14 x August 2018 ...
Страница 14: ...10 SteelCentral NetExpress Appliance Installation Guide Preparation Licensingstrategy ...
Страница 20: ...16 SteelCentral NetExpress Appliance Installation Guide Configuration Step 2 Log in to the web user interface ...
Страница 30: ...26 SteelCentral NetExpress Appliance Installation Guide Licensing Licensing multiple products ...
Страница 32: ...28 SteelCentral NetExpress Appliance Installation Guide Installation verification ...
Страница 37: ...SteelCentral NetExpress Appliance Installation Guide 33 ...