Rittal Micro Data Center Level E
23
7 Operation
EN
After expiration of the penalty time, press the
ON
key
at any time.
Enter the valid 6-digit primary or secondary code.
The
signal message appears once.
The following message appears: An invalid dual code
was entered during a previous opening attempt. The
signal message also appears: three times
Turn the bar handle within 4 seconds clockwise until it
reaches the limit.
Changing the dual code by the dual-code holder
Open the lock with the valid dual code (see page 22).
Press the
ON
key.
Press the
P
key.
Enter the valid dual code.
The
signal message appears.
Enter the new 6-digit first subcode.
The /
signal message appears twice.
Re-enter the new valid 6-digit first subcode.
The
signal message appears once.
Enter the new 6-digit second subcode.
The /
signal message appears twice.
Re-enter the new valid 6-digit second subcode.
The
signal message appears once.
Test the newly programmed dual code by closing and
reopening the lock.
If the first or second subcode was not confirmed cor-
rectly with the repeated input, the following signal mes-
sage appears three times
:
Repeat the action.
The sequence of the subcode and its repeated confir-
mation must be observed.
Changing from ordinary dual-code mode to paral-
lel mode: Changing the dual code to the primary
code
Open the lock with the valid dual code (see page 21).
Press the
ON
key.
Press the
P
key.
Re-enter the valid dual code.
The
signal message appears.
Press the
P
key.
Press the
0
key.
The
signal message appears once.
Pressing the
P
and
0
key combination deletes the
second subcode.
Closing
Turn the bar handle within 4 seconds clockwise until it
reaches the limit.
Time delay (TD) and opening window (OW) func-
tions
Time delay (TD) is designated as the period of time
which must elapse before the lock can be opened The
opening window (OW) is designated as the time period
during which the lock can be opened after the TD has
elapsed. Each valid code can be given a TD and an OW.
Activating/changing the TD/OW
Open the lock with the valid code.
Press the
ON
key.
Press the
P
key.
The
signal message appears.
Re-enter the valid code.
The
signal message appears.
Press the
1
key for the input of the TD/OW for:
– Primary code in parallel mode
– Primary code in delegated dual-code mode
– Dual code in ordinary delegated dual-code mode
Press the
2
key for the input of the TD/OW for:
– Secondary code in parallel mode
– Dual code in delegated dual-code mode
The
signal message always appears.
Enter a two-digit TD (01-99 minutes) and a single digit
OW (1-9 minutes).
Example: 092 for 9 minutes TD and 2 minutes OW.
The
signal message appears once.
Test the newly programmed TD and OW by closing
and reopening the lock.
Opening for programmed TD/OW
Press the
ON
key.
Enter the valid code.
The
signal message appears once.
Automatic start of the TD: The
signal message ap-
pears every 5 seconds.
After expiration of the TD: The
signal message ap-
pears every 5 seconds.
Automatic start of the OW: The
/
signal mes-
sage appears every 5 seconds.
Re-enter the valid code during the OW.
The
signal message appears once.
Turn the bar handle within 4 seconds clockwise until it
reaches the limit.
Pressing the
P
key within the OW cancels this function.
To reopen, the complete action must be repeated.
Three code inputs are possible within the OW. The com-
plete action must be repeated after the third incorrect in-
put. The TD/OW can be bypassed by using the inspec-
tion key (see page 24).
Deleting the programmed TD/OW
Open the lock with the valid code.
Press the
ON
key.