background image

Rite‑Hite

®

 

Installation/Service/Owner's Manual

  Dok‑Guardian™ HD Safety Barrier

Publication:

 AMEN00033 2019-03-29 

INSTALLATION
Wardens

Footprint: Standard

15.50

[393.70mm]

13.50in

16.00in

[406.40mm]

[342.90mm]

 C

 A

 B

 D

 E1

 E2

Footprint: Common

Receiver Warden

Storage Wardens

First Unit "A"

Middle Unit(s) "B"

Multiple units may be labeled "B"

End Unit "C"

Reference the survey drawing completed by the 

salesperson if it is available
The back of the unit (near the roller) is labeled with the 

width of each curtain and (for common footprints) a letter
1  The back side of all wardens should be flush (A) and 

measure the same distance (B) from the dock edge or 

equipment it is protecting (C)
Position the inside edge of the wardens even with the 

door jamb and the backs at least:

•  17in [432mm] from the dock edge (B), for units up to 

11ft-5in [348M] COW* (D)

•  30in [762mm] from the dock edge (B), for units up to 

11ft-6in to 16ft-5in [35m to 50m] COW (D)

Ensure the placement of the wardens do not interfere 

with any door operation

Footprint: Standard, go to Step 5.  

(ie1 Storage (E1), 1 Receiver (E2))

Footprint: Common, go to Step 2.

Unit "A":

  Position to begin the chain The COW 

between unit "A" and the first "B" unit must be within 

5in [127mm] of the width dimension on the back of 

unit "A"

Unit "B":

  Center each unit in the space available 

between the respective doors being serviced 

Arrange, in correct sequence, any "B" units that vary 

in COW Ensure the COW between the units is 

within 5in [127mm] of the width dimension labeled on 

the back of each unit's respective storage unit

Unit "C":

  Position unit "C" and the latch side warden 

to end the chain Ensure the COW between unit "C" 

and the latch side warden is within 5in [127mm] of the 

width dimension on the back of unit "C"

5  After the units are within their respective service ranges, 

shim the wardens as necessary to be plumb and level

6  Complete 

"Anchoring to Concrete*" (page 8)

Figure 5 

*COW= Clear Opening Width

Содержание Dok-Guardian HD

Страница 1: ...ETY 2 INSTALLATION Preparation 3 Change Orientation 4 Wardens 7 Interlock Interdeterrent OPTIONAL 9 Curtain 10 Electrical 11 OPERATION Extend Barrier 16 Store Barrier 16 MAINTENANCE Planned Maintenanc...

Страница 2: ...n this manual are covered by one or more of the following U S patents 7207370 7832451 7775252 6279276 8490668 7237591 8087443 8826963 and may be covered by additional pending U S and foreign patent ap...

Страница 3: ...squ ce que l unit s ont t compl tement install WARNING AVERTISSEMENT Spring under tension DO NOT unwind the roller spring Ressort sous tension NE PAS d rouler le rouleaux ressort NOTICE Do not install...

Страница 4: ...ian wardens to pull in the opposite direction 1 Separate the roller support A from the storage warden B by removing the 7 bolts washers and nuts C 2 Turn the roller support completely upside down and...

Страница 5: ...tain Lead Bar G G NOTE Pin orientation does not change for either pull direction Legs of handle and legs of pin must always point to one another Left to Right Pull NOTE Interdeterrent magnet is behind...

Страница 6: ...entered and does not get moved DO NOT overtighten nylock nuts Actuator should have freedom of movement Nylock nuts provided with actuator finish flush with the screw end L 1 9 7 4 5 6 10 11 12 Shown B...

Страница 7: ...for units up to 11ft 6in to 16ft 5in 3 5m to 5 0m C O W D Ensure the placement of the wardens do not interfere with any door operation Footprint Standard go to Step 5 i e 1 Storage E1 1 Receiver E2 Fo...

Страница 8: ...sively worn will ma anchor Using a drill bit that is too large will reduce the anc Use compressed air to blow the concrete dust out of the h not be able to tighten the anchor completely Using the Impa...

Страница 9: ...ent plate B 3 Remove curtain lead bar A 4 Using reinforcement plate B as a template drill a 1 2in 13mm hole through the warden not shown to pass the threaded body of the switch C to the back side of t...

Страница 10: ...acket to receiver warden c Move the latch bracket away from the storage warden the desired number of holes d Tighten the 3 bolts securing the latch bracket to receiver warden e Refasten the latch brac...

Страница 11: ...80 0 100 80 0 125 ANGLES 1 DEG ITEM QTY PART NUMBER DESCRIPTION 1 1 BUD PN 1339 DG ENCL ABS 6X6X3 NEMA4X 2 1 BUD PNX 91438 BACKPANEL MACH JBOX 3 4 SCR RHMS PHLP M3X5mm ZNC 4 2 SCR 8 1 4 ZNC 5 1 REF 38...

Страница 12: ...Dok Guardian HD Safety Barrier Installation Service Owner s Manual Rite Hite 12 Publication AMEN00033 2019 03 29 INSTALLATION Electrical Interlock UCR Controls OPTIONAL 1203E001 pdf...

Страница 13: ...Rite Hite Installation Service Owner s Manual Dok Guardian HD Safety Barrier Publication AMEN00033 2019 03 29 13 INSTALLATION Electrical Interlock Gen2 Controls OPTIONAL 1203E001 pdf...

Страница 14: ...Dok Guardian HD Safety Barrier Installation Service Owner s Manual Rite Hite 14 Publication AMEN00033 2019 03 29 INSTALLATION Electrical Interdeterrent UCR Controls OPTIONAL 1203E001 pdf...

Страница 15: ...Rite Hite Installation Service Owner s Manual Dok Guardian HD Safety Barrier Publication AMEN00033 2019 03 29 15 INSTALLATION Electrical Interdeterrent Gen2 Controls OPTIONAL 1203E001 pdf...

Страница 16: ...curtain across the opening 2 Latch the curtain lead bar attached to the end of the curtain A1 into the latch bracket A2 at the opposite side of the opening 3 Insure the curtain lead bar is fully enga...

Страница 17: ...the curtain and allow it to be rolled up by the roller assembly Watch for any binding or loose edges on the curtain that may get caught or inhibit the curtain from properly rolling up Replace curtain...

Страница 18: ...nsert the screwdriver into the small hole on the top of the roller assembly and down into 1 of the 2 holes in the roller tube Make sure the screwdriver is inserted securely before letting go of the ro...

Страница 19: ...Rite Hite Installation Service Owner s Manual Dok Guardian HD Safety Barrier Publication AMEN00033 2019 03 29 19...

Страница 20: ...HHMS 1 2 13X1 1 2 GR5 ZNC 8 17 74150001 WSHR FLAT 1 2X1 3 8X7 64 ZNC 9 10 55650004 NUT HEX NYL LOCK 1 2 13 ZNC 10 3 67900048 BLT CARG 1 2 13X1 1 2 GR5 ZNC 11 28 65300028 PLUG PLSTC YLW 9 16 12 3 67860...

Страница 21: ...r Width Opening 28200047 Curtain DGHD 12ft 6in to 13ft 5in Clear Width Opening 28200048 Curtain DGHD 13ft 6in to 14ft 5in Clear Width Opening 28200049 Curtain DGHD 14ft 6in to 15ft 5in Clear Width Ope...

Страница 22: ...dle Unit 1 Latch Bracket 1 Storage Warden No Receiving Warden FIRST UNIT Note absence of receiving latch receiving post MIDDLE UNIT Note absence of receiving post END UNIT Note presence of 2 receiving...

Страница 23: ...CH INTERLOCK NO LATCH NONE NO LATCH NONE HD LATCH 1041 XXX INTERDETERRENT HD LATCH INTERLOCK HD LATCH INTERDETERRENT NO LATCH INTERLOCK NO LATCH NONE NO LATCH NONE HD LATCH 1041 XXX None HD Latch Inte...

Страница 24: ...ERDETERRENT Interlock 12420030 BAR ASSY CRTN INTERLOCK NO INTERDETERRENT NO INTERLOCK INTERDETERRENT INTERLOCK DESCRIPTION PART 1 1 1 1 BAR CURTAIN EXTEND DOK GRDN 12420025 2 1 1 SCR RHMS PHLP 10 24 X...

Страница 25: ...5 PARTS Interdeterrent Switch 76210073 SWITCH ASSY INTERDETERRENT 53760029 KIT MAG INTERD DOK GUARDIAN DESCRIPTION 1 SW MAG REED NO 0 5A 8ft CORD 2 SCR RHMS PHLP 10 24 X2 SS 3 NUT HEX NYL LOCK 10 24 Z...

Страница 26: ...N 6 2 STANDOFF NYLON PCB ADHSV 1 4in 7 1 PCB ACTUATOR DOK GUARDIAN 8 1 SHRD SW INTERLOCK 10MM DKGRDN 9 2 SCR RHMS PHLP 8 32X1 ZNC 10 2 NUT HEX SERRATED 8 32x1in Z 11 1 LVR LINKAGE INTRLCK DKGRDN 12 2...

Страница 27: ...Rite Hite Installation Service Owner s Manual Dok Guardian HD Safety Barrier Publication AMEN00033 2019 03 29 27...

Страница 28: ...s premises for the purpose of repairing or replacing the Product or y return of the Product to the Rite Hite F O B Rite Hite s factory NOT WARRANTED Rite Hite does not warrant against and is not resp...

Отзывы: