Pub. No. 1120-R5 — June 2000
21
1L2 (White)
G (Green)
Motor
Thermal
Overload
Motor – 3/4 HP
@2850/3450 R.P.M.
120V 1 PH 50/60 Hz
Intermittent Duty
(Thermally Protected
With Automatic Reset)
Use Minimum #12 Gage, 60
°
/ 75
°
C Copper
Wire/100 Ft. Of Run – 20 Amp Circuit 120V.
Consult Local Code.
– Wire Termination
Wire Nut Or Equal Device
MOTOR LEAD CONNECTIONS
L1 N
G
1L1 N
G
NOTES:
1. PB1 “RAISE” Switch Is 1 HP Rated.
2. Optional Recycle Limit Switch LS1 Is Automatically Operated By
The Location Of The Hydraulic Cylinder. This In Turn Controls
Flow To LS2 Which Is Operated By The Lip Assist Push Rod
Assy. Both Switches Are 1 HP Rated (APB-1000 Only).
3. For Field Wiring See Dwg. #AI-1839.
LS1 (N.O.H.C.)
Restrictor Switch
(Held Closed)
LS2 (N.O.)
ARTD Limit Switch
(Automatic Return To Dock)
Optional (APB-1000 Only)
2L1
(White
w/Red
Marker)
T1/P1
(White
w/Red
Marker)
1L1
(Black)
2L1
(Black)
4424
1L1 (Black)
T1 (Black)
One Leveler Per Overload Protection Device.
(Ref. N.E.C. 1996 Para. 430-110 (C)) Consult Local Code.
A Branch Circuit Disconnect Shall Be Located No More
Than 50' From The Control Box And Must Be Visible.
(Ref. N.E.C. 1996 Para. 430-102 (A) And Article 100).
BRANCH
CIRCUIT
DISCONNECT
From Customer Main Power & Safety
Protection Device 120V 1 PH 50/60 Hz.
(Fused Disconnect Supplied By Others)
(Must Use Either 20 Amp Dual Element
Fuse Or 20 Amp Inverse Time Circuit
Breaker).
PUSHBUTTON
CONTROL BOX
G (Green)
G (Green)
1L2 (White)
T5
T4
T2
T8
T3
P2
P1
T1/ P1 (Black)
T1/ P1 (White / Red)
2L1
(White / Red)
2L1 (Black)
1L1 (Black)
1L1 (Black)
Motor
MOTOR JUNCTION BOX
ELECTRICAL SCHEMATIC 120V WITH AUTOMATIC RETURN TO DOCK (ARTD) OPTION
4424 Rev C
FIGURE 23 — ELECTRICAL SCHEMATIC, 120V WITH ARTD
APB-1000/Rev5 6/1/00 7:48 AM Page 21
Содержание APB-1000
Страница 4: ...APB 1000 Rev5 6 1 00 7 48 AM Page d...
Страница 6: ...APB 1000 Rev5 6 1 00 7 48 AM Page ii...
Страница 43: ...APB 1000 Rev5 6 1 00 7 48 AM Page 37...