Riptide Manta SuperPro Скачать руководство пользователя страница 9

COnTrOl Panel OPeraTIOns

9

user preferenCes

There are several aspects of spa operation that you 

can customise using the User Preferences sub menu 

from the main control panel.
Press tempº + or tempº− then variable speed 
drive
 (vsp) then light (each press within 3 

seconds). At this point if 

USr

 is not showing on the 

display press tempº + or tempº− until 

USr

 appears. 

Then press vsp to enter the User Preferences sub 

menu.
Once in the User Preferences sub menu press 
tempº + or tempº− or to cycle between these 

settings:

Sr

 - suppress reminders

When set to 

Sr.Y

  reminders are never displayed on 

the panel. When set to 

Sr.n

  reminders are displayed 

on the control panel periodically.

tc

 - temperature in °C (Celsius)

When set to 

tc.Y

  temperatures are displayed in 

°C (Celsius). When set to 

tc.n

  temperatures are 

displayed in °F (Fahrenheit).

24

 - 24 hour time display

When set to 

24.n

  time is displayed as a 12 hour 

(am/pm) clock. When set to 

24.Y

  time is displayed 

as a 24 hour clock. 

cc

 - Clean up Cycle duration

When set to 

cc.D

  clean up cycles are disabled. 

When set to 

cc.1

  through 

cc.4

   the number 

indicates how many hours each clean up cycle 

will run.

edItInG

 

user preferenCes

View the setting you wish to adjust (see User 
Preferences).

The left 2 characters (before the decimal point) tell you 
what setting you are viewing or editing. The character 
after the decimal point tells you the value of that setting 
(for example: 

.Y

  for yes, 

.n

  for no).

Press 

vsp 

to switch editing on and the value will flash. 

Press 

vsp 

once again to turn editing off and it will stop 

flashing.

When editing the value (when it is flashing) use the 

tempº + or tempº− 

to change the value to the setting 

you want. After you have changed the value press 

vsp 

again to save the change - the value will then stop 
flashing.

If you don’t make any changes during editing it will time 
-out after 30 seconds. If you press light to back out of 
the menu or pause long enough for it to time-out while 
a value is flashing, the changes you were making to that 
setting won’t be saved. However, changes you made to 
previous settings will be saved.

auxIlIary Control panel

The auxiliary control panel operates the Variable 
Speed Drive (VSP): ON/OFF function and jet speed.

The Variable Speed Drive must first be turned on 
at the Main Control Panel and then turned on at 
the Auxiliary Control Panel. The counter current will 
then start up and go to power level 1. You can then 
increase the counter current speed 1-10 and then 
back down 10-1.

rIsK of damaGe warnInG:
NEVER turn the Variable Speed Drive off at the Main 
Control Panel without first switching it off at the 
Auxiliary Control Panel.

Содержание Manta SuperPro

Страница 1: ...Owner s Manual Riptide Nautilus SuperPro Manta SuperPro Swim Spas Exercise Pools 2012 Euro 240v 50 Htz...

Страница 2: ...ump 8 Ozone Generator 8 Auxiliary control panel 9 Diverter controls 9 User Preferences 9 Editing User Preferences 9 TROUBLESHOOTING GUIDE Diagnostic Messages 10 Periodic Reminder Messages 12 Diagnosti...

Страница 3: ...gs or medication can greatly increase the risk of fatal Hypothermia in a swim spa b The causes symptoms and effects of Hypothermia may be described as follows Hypothermia occurs when the internal temp...

Страница 4: ...ed to concrete wood non slip tile or linoleum Outdoor Considerations When selecting an outdoor site several things should be considered Firstly avoid selecting a site where excessive water may contact...

Страница 5: ...ully open position A valve that is half closed will result in INSTALLATION SET UP a noisy pump due to lack of water flow 5 Fill the pool Fill the swim spa to approximately the halfway point on the ski...

Страница 6: ...an automatic timer switch and operational safety features to ensure a safe and relaxing swim spa experience Heater control You can set the water temperature to suit the activity hot for just relaxing...

Страница 7: ...de Both the Std and Ecn icons display in this mode During this time you can press the Mode button to revert back to Economy mode immediately Sleep mode heats the water to 11 C only during filter cycle...

Страница 8: ...F2 icon will light when filter 2 is running If you would like to select continuous filtration set the filter 1 start and end times to be the same In this case the filter 2 start time only operates whe...

Страница 9: ...nces The left 2 characters before the decimal point tell you what setting you are viewing or editing The character after the decimal point tells you the value of that setting for example Y for yes n f...

Страница 10: ...nuer to operate normally The control panel will be disabled until power returns The clock time may have to be reset after reconnection All other spa settings will be preserved DO NOT ENTER THE WATER R...

Страница 11: ...r level in spa Add water if necessary If the water is at the correct level make sure the pumps have been primed Press any button to reset The priming mode will last up to 4 minutes and the spa will be...

Страница 12: ...ery 180 days Every 180 days Every 365 days As required Test and adjust pH chemical levels as per manufacturer s instructions Test and adjust sanitiser chemical levels as per manufacturer s instruction...

Страница 13: ...ault time setting has switched of the jets The pump motor is overheating Water pump is sucking in air Filter cartridge needs cleaning There is no cover on the spa creating heat loss Heater is faulty J...

Страница 14: ...LORINE SHOCK MAINTENANCE 3 pH Control Proper pH balance is extremely important in controlling bacteria providing water that s comfortable for the user and in preventing damage to the swim spa and its...

Страница 15: ...the range of 7 4 7 6 6 After the water has circulated for approximately a quarter of an hour retest the chlorine level in your water and add the correct amount to raise the level to between 3 5 PPM S...

Страница 16: ...Bisulphate pH Reducer 119 54g 239 09g 358 63g 478 18g 597 72g 717 26g 836 81g 956 35g 1075 90g 1195 44g 4 981 Increase Sodium Bicarbonate Alkalinity Increaser 99 62g 199 24g 298 86g 398 48g 498 10g 59...

Страница 17: ...and gradual breakdown of headrest material due to the corrosive effect of chlorine and ozone CHANGING YOUR SWIM SPA WATER Depending on usage your spa section water will need to be changed approximate...

Страница 18: ...is being used less than once per month then you may wish to lower the temperature MAINTENANCE setting of the spa section by approximately 5 C Lowering the temperature on your spa will cut your cost o...

Страница 19: ...someone other than an authorised Riptide technician will not be covered by your warranty NON GUARANTEE SERVICE We recommend having an authorised Riptide technician perform all repairs on swim spa tha...

Страница 20: ...be free from defects in materials and workmanship for a period of one year from the Swim Spa s delivery date Riptide Pools Limited United Kingdom 5Year Structural 5Year Surface Warranty Riptide warra...

Страница 21: ...a when purchased and originally installed or relocated in the boundaries of the country of purchase The Riptide swim spa warranty terminates upon any transfer of ownership or if the swim spa is instal...

Страница 22: ...Robjohns Road Chelmsford Essex CM1 3AG United Kingdom If possible please enclose a photocopy of the original purchase contract receipt to negate the need for inspection on service calls Name Address P...

Отзывы: