dIaGnostIC messaGes
Control Panel Message
Definition
Action required
No message on display
OHH
OH5
ICE
SnA
/
Snb
SnS
HFL
LF
Power has been disconnected
from the spa
Overheat - the spa will have shut
down. One of the sensors has
detected that the heater has
reached a temperature of 47.8°C.
Overheat - the spa will have shut
down. One of the sensors has
detected that the spa water is
43.3°C.
Potential freeze condition
detected.
Spa is shut down. The sensor that
is plugged into A or B as indicated
is not working.
Sensors are out of balance. If
this message is alternation with
the temperature it may just be
a temporary condition. If the
display shows only this message
(periodically blinking the spa will
have shut down.
A substantial difference between
the temperature sensors has been
detected. This could indicate a
water flow problem.
Persistant low water flow problems
(will display this message on
the fifth occurrence of the
HFL
message within 24 hours). The
heater will have shut down but
other spa functions will continuer
to operate normally.
The control panel will be disabled
until power returns. The clock
time may have to be reset after
reconnection. All other spa
settings will be preserved.
DO NOT ENTER THE WATER.
Remove the spa cover and allow
the water to cool. Once the heater
has cooled, reset by pushing any
button on the control panel. If the
spa does not reset, disconnect
from the power and call your
dealer for assistance.
DO NOT ENTER THE WATER.
Remove the spa cover and allow
the water to cool. At 41.7°C the
spa should automatically reset.
If the spa does not reset,
disconnect from the power and
all your dealer for assistance.
No action required. The pumps will
automatically activate regardless of
spa status.
If the problem persists contact
your dealer. This message may
appear temporarily in an overheat
situation and will disappear when
the heater cools.
If the problem persists contact
your dealer.
Check water level in spa. Add
water if necessary. If the water is
at the correct level make sure the
pumps have been primed. Press
any button to reset.
Check water level in spa. Add
water if necessary. If the water is
at the correct level make sure the
pumps have been primed. Press
any button to reset.
TrOuBlesHOOTInG GuIDe