background image

PAGE 4

Chapter 4: Quickstart guide

Prior to using this quickstart guide or operating the equipment in any way, it is 

highly suggested 

that the user reads all safety 

information in chapter 3.
1.  Press 

Power Button

 to turn on the OTDR. 

2.  Touch the Auto Test icon to enter the OTDR function.
3.  Connect the fiber to the appropriate port (SM SC/APC OTDR Optical Port).
4.  Touch the wavelength field on the display to open the wavelength list and choose the desired wavelength for the test.

NOTE

To test in Dual Mode, select both wavelengths. Wavelengths are selected if they are highlighted in dark gray.

If the launch and receive fiber lengths are unknown: 

1.  Leave the fiber launch and receives lengths set to 0. The OTDR will automatically detect any events it detects and display 

them when the results are shown. Any launch or receive events will be displayed as normal events.

If approximate Launch/Receive fiber length(s) is known:

1.  Enter the desired fiber launch and receive lengths in meters or feet. Select the feet option on the input screen if desired.
2.  Tap "Begin Test" and the OTDR will start a test using the selected wavelength(s), allowing the OTDR to determine the most 

appropriate range and pulse width. (Auto Test will set the averaging time to the best option dynamically, typically 60 sec.)  

3.  The schematic view will be shown once the test has completed. Review your results and/or save by clicking the save icon and 

naming your trace. (Refer Fig 8.5 for icon options)

NOTE

The Schematic view displays the trace with colored (Pass/Fail) events and allows the technician to quickly scroll 

through all events and fiber spans. The Trace View displays the trace with the parameters listed and loss and distance 

measurements displayed. The Event List displays the trace with numbered events and an interactive event table. Cycle 

through each of the screens by touching the icons below:

Chapter 5: Inspection and Identification

5.1  Inspection 

Before shipment, quality inspection proved that the instrument was in perfect working order and free of defects. The shipping 

carton contains the following:
1.  OTDR with Protective boot 
2.  USB 5 Volt Charger and Cable
3.  User Manual
4.  FC OTDR Adapter 
5.  Hard Carry Case for Instrument

5.2  Identification and Configuration

The instrument’s Model/Part Number, Serial Number and Date of 

Manufacture are indicated on a label located on the back of the unit. 

The instrument’s history is filed at the factory by model/part number 

and serial number. The unit's serial number is also located on the top 

plate just above the USB Port.

 Fig 5.1

Содержание ODM OTDR 800

Страница 1: ...LITY IS ASSUMED BY RIPLEY TOOLS FOR ITS USE NOR FOR ANY INFRINGEMENTS OF PATENTS OR OTHER RIGHTS OF THIRD PARTIES THAT MAY RESULT FROM ITS USE NO LICENSE IS GRANTED BY IMPLICATION OR OTHERWISE UNDER A...

Страница 2: ...arning alerts to situations that could cause personal injury CAUTION A caution alerts to situations that may cause damage to the equipment or produce poor testing conditions resulting in inaccurate te...

Страница 3: ...e the AC adapter when there are signs of damage to the enclosure or cord Ensure that you are using the correct charger for the local line voltage Do not use any other charger than the one provided wit...

Страница 4: ...e range and pulse width Auto Test will set the averaging time to the best option dynamically typically 60 sec 3 The schematic view will be shown once the test has completed Review your results and or...

Страница 5: ...Display The unit is equipped with a 3 5 color TFT resistive touch display ODM OTDR CUSTOM TEST VFL OFF VIEW TRACE AUTO TEST Fig 6 3 AUTO TEST MODE Tap this feature to run a simple Optical Time Domain...

Страница 6: ...ok for the presence of a red spot on the paper 7 2 VFL Description The Visual Fault Locator emits visible red light at the 650 nm wavelength Its intended function is to allow an operator to identify t...

Страница 7: ...the wavelength list and choose the desired wavelength for the test Select either a single wavelength or two for dual mode operation Wavelengths are selected when they are highlighted in dark gray If t...

Страница 8: ...gth Once the first wavelength has finished the second test using the other wavelength will begin again at 0 Set Launch Receive Length Tap the textbox containing the fiber length to change it Enter the...

Страница 9: ...r the range of the values and set them using the same steps as for the test parameters NOTE There is an ORL and a Reflection Threshold setting The ORL is the return loss for the entire link system and...

Страница 10: ...ews low medium and high To set the event sensitivity tap the textbox for the sensitivity setting select the desired setting and then tap OK The lowest setting possible should be used to help filter ou...

Страница 11: ...l Parameters TRACE SETTINGS Shows Current Trace Parameters and Allows User to Edit Parameters for a New Test RUN RUN Runs a New Trace or Starts Live Mode Trace View Only TRACE VIEW Opens Trace View Sc...

Страница 12: ...ed end of the fiber under test The last row is with the type Link includes data that is relevant to the entire system link full fiber under test P or F Pass or Fail If any threshold is not met for an...

Страница 13: ...ss for the link is displayed System ORL 8 8 Event Analysis NOTE When using the Event Table or Schematic View it is necessary to keep in mind that Event Analysis provides approximate Loss and Distance...

Страница 14: ...available options Proceed to enter the rest of the test parameters as desired and then begin the test The two wavelength tests will run consecutively after one another After the first completes the s...

Страница 15: ...the display Set point number one by tapping the cursor select shown as an A or B letter in upper or lowercase refer to figure 8 8 button to toggle between the cursors until lowercase a is selected Mov...

Страница 16: ...roperly The green LSA Indicator Line overlays the backscatter of the Trace properly Chapter 9 Project Management 9 1 Project Management Description Project Management allows the user to save a set of...

Страница 17: ...reen Refer to Figure 9 1 Ensure that the right Project is highlighted because once it is deleted the project and all files associated with the project cannot be restored NOTE Delete must be held for a...

Страница 18: ...to the computer with the included USB cable NOTE The two plugs in the top right corner of the computer software screen should show as connected and green Highlight the file to be uploaded using the n...

Страница 19: ...nm 5 nm CONNECTOR TYPE 2 5 mm Universal OUTPUT POWER 1 mW Max LASER SAFETY CLASS II FDA21 CFR1040 10 1040 11 IEC 825 1 1993 Ripley Tools reserves the right to change specifications without notice Cha...

Страница 20: ...ode and Single Mode Fiber Construction of Fiber Optic Cables Connectors and Ferrule Types 2 Connector Inspection IEC 61300 3 35 Standard Understanding the IEC Specification Inspection Methods Connecto...

Отзывы: