Chapter 3: Safety

Prior to operating the equipment in any way, it is highly suggested the user reads all safety information.

The information in this chapter pertains to safety consideration of OTDRs in general. This product has been designed and tested 

in accordance with the manufacturer’s safety standards, and has been supplied in a safe condition. 
Information contained in this document must be followed by the user to ensure safe operation and to maintain the functionality of 

the product. Failure to follow these safety warnings and cautions may result in harm to the user and/or damage to the instrument.

WARNING

Personnel should always be aware when working with fiber optic test equipment that active fibers may be present and 

therefore, infrared optical energy may be present.   

WARNING

Never look directly into the end of a connected fiber optic cable or the fiber optic interface of optical test equipment; to 

do so may expose the user to laser radiation and may result in personal injury.

WARNING

To Prevent Fire or Shock Hazard:

•  Do not install battery types other than those supplied by the manufacturer.
•  Do not use the charger without the proper batteries installed.
•  Do not expose the battery charger to rain or excessive moisture.
•  Do not use the AC adapter when there are signs of damage to the enclosure or cord.
•  Ensure that you are using the correct charger for the local line voltage.
•  Do not use any other charger than the one provided with this instrument.
•  Do not puncture batteries.
•  Do not incinerate batteries.
•  All batteries should be disposed of in a proper manner.

Failure to follow these caution statements may cause unsafe conditions for the operator and/or equipment, and may void 

the warranty. 

CAUTION

Fiber-optic connectors are easily contaminated or damaged. The connection to the OTDR is by physical contact types of 

connections. Dirty or damaged connectors may impair the instruments capabilities at a minimum, and at worst, result 

in the need to return the OTDR to the factory for unwarranted repairs. Prior to making any connection to the unit, ensure 

that all proper cleaning procedures have been followed. Use APC Finish Connectors Only -- DO NOT insert UPC connectors 

into the optical ports. 

CAUTION

The OTDR is equipped with a protection circuit to avoid damage from live fiber connections. Therefore, the instrument 

will not operate properly with active fibers. Even with circuit protection, high power output from EDFA’s or other 

equipment can damage detectors and should never be connected to the OTDR.  If a live fiber is connected to the OTDR 

and a scan is attempted, a warning dialog will be displayed as in Fig. 3.1. Immediately remove the live fiber from the OTDR 

and press select to clear the message.

 Fig 3.1

Содержание ODM OTDR 800

Страница 1: ...LITY IS ASSUMED BY RIPLEY TOOLS FOR ITS USE NOR FOR ANY INFRINGEMENTS OF PATENTS OR OTHER RIGHTS OF THIRD PARTIES THAT MAY RESULT FROM ITS USE NO LICENSE IS GRANTED BY IMPLICATION OR OTHERWISE UNDER A...

Страница 2: ...arning alerts to situations that could cause personal injury CAUTION A caution alerts to situations that may cause damage to the equipment or produce poor testing conditions resulting in inaccurate te...

Страница 3: ...e the AC adapter when there are signs of damage to the enclosure or cord Ensure that you are using the correct charger for the local line voltage Do not use any other charger than the one provided wit...

Страница 4: ...e range and pulse width Auto Test will set the averaging time to the best option dynamically typically 60 sec 3 The schematic view will be shown once the test has completed Review your results and or...

Страница 5: ...Display The unit is equipped with a 3 5 color TFT resistive touch display ODM OTDR CUSTOM TEST VFL OFF VIEW TRACE AUTO TEST Fig 6 3 AUTO TEST MODE Tap this feature to run a simple Optical Time Domain...

Страница 6: ...ok for the presence of a red spot on the paper 7 2 VFL Description The Visual Fault Locator emits visible red light at the 650 nm wavelength Its intended function is to allow an operator to identify t...

Страница 7: ...the wavelength list and choose the desired wavelength for the test Select either a single wavelength or two for dual mode operation Wavelengths are selected when they are highlighted in dark gray If t...

Страница 8: ...gth Once the first wavelength has finished the second test using the other wavelength will begin again at 0 Set Launch Receive Length Tap the textbox containing the fiber length to change it Enter the...

Страница 9: ...r the range of the values and set them using the same steps as for the test parameters NOTE There is an ORL and a Reflection Threshold setting The ORL is the return loss for the entire link system and...

Страница 10: ...ews low medium and high To set the event sensitivity tap the textbox for the sensitivity setting select the desired setting and then tap OK The lowest setting possible should be used to help filter ou...

Страница 11: ...l Parameters TRACE SETTINGS Shows Current Trace Parameters and Allows User to Edit Parameters for a New Test RUN RUN Runs a New Trace or Starts Live Mode Trace View Only TRACE VIEW Opens Trace View Sc...

Страница 12: ...ed end of the fiber under test The last row is with the type Link includes data that is relevant to the entire system link full fiber under test P or F Pass or Fail If any threshold is not met for an...

Страница 13: ...ss for the link is displayed System ORL 8 8 Event Analysis NOTE When using the Event Table or Schematic View it is necessary to keep in mind that Event Analysis provides approximate Loss and Distance...

Страница 14: ...available options Proceed to enter the rest of the test parameters as desired and then begin the test The two wavelength tests will run consecutively after one another After the first completes the s...

Страница 15: ...the display Set point number one by tapping the cursor select shown as an A or B letter in upper or lowercase refer to figure 8 8 button to toggle between the cursors until lowercase a is selected Mov...

Страница 16: ...roperly The green LSA Indicator Line overlays the backscatter of the Trace properly Chapter 9 Project Management 9 1 Project Management Description Project Management allows the user to save a set of...

Страница 17: ...reen Refer to Figure 9 1 Ensure that the right Project is highlighted because once it is deleted the project and all files associated with the project cannot be restored NOTE Delete must be held for a...

Страница 18: ...to the computer with the included USB cable NOTE The two plugs in the top right corner of the computer software screen should show as connected and green Highlight the file to be uploaded using the n...

Страница 19: ...nm 5 nm CONNECTOR TYPE 2 5 mm Universal OUTPUT POWER 1 mW Max LASER SAFETY CLASS II FDA21 CFR1040 10 1040 11 IEC 825 1 1993 Ripley Tools reserves the right to change specifications without notice Cha...

Страница 20: ...ode and Single Mode Fiber Construction of Fiber Optic Cables Connectors and Ferrule Types 2 Connector Inspection IEC 61300 3 35 Standard Understanding the IEC Specification Inspection Methods Connecto...

Отзывы: