65
Comparate
Example: To achieve operation as shown in the diagram below, make the
settings as follows.
Set “Node Number” to “4” and create Line 1 in accordance with DIN 4150-3.
Set “Limit Node 1” to
①
, “Limit Node 2” to
②
, “Limit Node 3” to
③
, and
“Limit Node 4” to
④
as shown in the chart.
Node Number 4
Limit Node 1
Frequency 1.0 Hz
PPV 20.00 mm/s
Limit Node 2
Frequency 10.0 Hz
PPV 20.00 mm/s
Limit Node 3
Frequency 50.0 Hz
PPV 40.00 mm/s
Limit Node 4
Frequency 100.0 Hz
PPV 50.00 mm/s
Caution
In this example, detection of a dominant
frequency of less than 1.0 Hz will not trigger
comparator operation.
Содержание VM-56
Страница 2: ......
Страница 39: ...27 Preparations System screen Clock settings screen...
Страница 41: ...29 Preparations System screen Backlight LCD settings screen...
Страница 43: ...31 Preparations System screen Execution confirmation screen...
Страница 54: ...42 Reading the Display 1 channel display 3 channel display...
Страница 100: ...88 Serial Interface Follow the wizard to complete the installation Screens during installation are as follows...
Страница 101: ...89 Serial Interface Depending on your environment Windows Security may be dis played Click on Install or Continue...
Страница 175: ...163 Specifications 175 Front panel 175 9 2 40 3 5 1 2 Right side panel Top panel Unit mm Dimensional Drawing of VM 56...
Страница 178: ...166 Specifications Unit mm Dimensional Drawing of L bracket plate VP 54L 6 5 11 65 4 M4 countersunk holes 70 20 t 2 9 80...
Страница 179: ......
Страница 180: ...No 62991 18 08 This product is environment friendly It does not include toxic chemicals on our policy...