background image

Remote Display Installation Manual 

– Software Version 4.x

 

 

D300-602-202                                                                                                              Page 39 

 

5.4.23.  Protocol 23: Flintab 

 

Normal Operation: 

 

Character 
Number 

10 

Description 

S

1

 

S2

 

S

ign

 

W

e

igh

W

e

igh

W

e

igh

W

e

igh

W

e

igh

W

e

igh

CR

 

LF

 

 

Function 

Description 

S1 

B = Gross, N = Net 

S2 

# = Motion, Space = Stable 

Sign 

Represents the sign of the weight reading (space for positive, 
dash (-) for negative. 

Weight 

The numbers to be displayed on the remote display.The weight 
value is 5 digits plus an optional decimal point. If a decimal 
point is not used then the weight field shortens to only 5 
characters. This means the overall string is 1 character shorter 

CR 

Carriage return character (ASCII 0DH). 

LF 

Line feed character (ASCII 0AH). 

 

Overload / Underload: 

 

Character 
Number 

10 

Description 

O

 

L

 

CR

 

LF

 

 

Содержание D32 series

Страница 1: ...D32x XD30 Remote Display Manual D300 601 200...

Страница 2: ...ssion of Rinstrum Pty Ltd Disclaimer Rinstrum Pty Ltd reserves the right to make changes to the products contained in this manual in order to improve design performance or reliability The information...

Страница 3: ...GS AND SAFETY 7 3 1 General 7 3 2 Electrical Safety 7 3 3 Cleaning 7 4 INSTALLATION 8 4 1 General Setup Information 8 4 2 Panel Mounting D32x Only 8 4 3 Cable Connections 9 4 4 DC Power 9 4 5 D32x RS...

Страница 4: ...sed by the transmitting device This manual contains information on the installation of this remote display 1 1 Approvals CE FCC and C tick approved 1 2 Features The remote display is fitted with an al...

Страница 5: ...Version Unit Dim 160 W x 75 H x 30 D mm Pack Weight 0 34kg Panel Mount Case Materials Plastic Version ABS Silicon Rubber Nylon Acrylic no halogen used Stainless Steel Version Unit Dim 200 W x 115 H x...

Страница 6: ...y PBT Pack Weight Basic remote 2 0kg Display Display Type 20mm LCD display LED backlight Number Digits 6 Digit Size 20mm Power Input Standard Input 4 8 to 24VDC 2 5VA max Variants AC AC Power supply 1...

Страница 7: ...ower or switching circuits 3 2 Electrical Safety For your protection all mains electrical hardware must be rated to the environmental conditions of use Pluggable equipment must be installed near an ea...

Страница 8: ...ar housing accessories Connect the serial and power cables to the instrument If using an RS 232 to RS 485 converter connect the converter between the serial cable and the remote display serial port co...

Страница 9: ...minals and may make for a neater job Warning Care should be taken when depressing the levers on the screwless connectors to prevent sideways movement and possible damage Use only appropriate tools eg...

Страница 10: ...lay Installation Manual Software Version 4 x Page 10 D300 602 202 4 5 D32x RS 232 Serial Auxiliary Connection Remote Display As a minimum the RXD and GND pins need to be connected to TXD and GND on th...

Страница 11: ...Remote Display Installation Manual Software Version 4 x D300 602 202 Page 11 Direct Personal Computer Link PC COM 1 DB9 PC COM 2 DB25...

Страница 12: ...lay Installation Manual Software Version 4 x Page 12 D300 602 202 4 6 XD30 RS 232 Serial Auxiliary Connection Remote Display As a minimum the RXD and GND pins need to be connected to TXD and GND on th...

Страница 13: ...Remote Display Installation Manual Software Version 4 x D300 602 202 Page 13 Direct Personal Computer Link PC COM 1 DB9 PC COM 2 DB25...

Страница 14: ...RFI immunity and minimise earth loops and cross talk interference between instruments For full EMC or for RFI immunity termination of the cable shields at the earth lug is very important The earth lu...

Страница 15: ...Odd parity 7 data bits 1 or 2 stop bits M ark 7 M71 M72 Mark parity 7 data bits 1 or 2 stop bits S pace 7 S71 S72 Space parity 7 data bits 1 or 2 stop bits 5 2 Delimiters The instrument responds to a...

Страница 16: ...nstrum 4 Ranger D Rinstrum 5 PCMODE Custom software 6 R series register write GSE Rinstrum 7 Avery string 7 Avery L105 8 Gedge C2 Gedge 9 Gedge C3 Gedge 10 AD standard string A D 11 AD4531 A D 12 Tole...

Страница 17: ...sables the 10 display timeout ie forcing the display to lock on Weight These seven characters are a string containing the current weight including the decimal point If there is no decimal point then t...

Страница 18: ...ing the current weight including the decimal point If there is no decimal point then the first character is a space Examples 300 with a leading space would represent 300 units 3 00 Is another acceptab...

Страница 19: ...ng space would represent 300 units 3 00 Is another acceptable string note that when the decimal point is added the leading space is removed S1 Can be G N U O E representing Gross Net Underload Overloa...

Страница 20: ...STX Start of Transmission Character ASCII 02H Sign Represents the sign of the weight reading space for positive dash for negative Weight These seven characters are a string containing the current wei...

Страница 21: ...e display will show text These eight characters can include a decimal point and a leading minus to indicate sign Example 300 would represent 300 units 3 00 a decimal point and minus sign can be used C...

Страница 22: ...of the unit to display the message Note the unit will respond to its address or a message for address 00 broadcast Command 0 1 Must be 12 ASCII 31H ASCII 32H Register 0 3 Must be 000E ASCII 30H ASCII...

Страница 23: ...The numbers to be displayed on the remote display These seven characters can include a decimal point and a leading minus to indicate sign E g 300 with leading spaces would represent 300 units 3 00 Is...

Страница 24: ...characters can include a decimal point and a leading minus to indicate sign E g 00000300 with leading zeroes would represent 300 units 00003 00 Is another acceptable string this time with a decimal p...

Страница 25: ...e eight characters can include a decimal point and a leading minus to indicate sign E g 00000300 with leading zeroes would represent 300 units 00003 00 Is another acceptable string this time with a de...

Страница 26: ...Net weight and off for all other weights Sign The sign of the weight reading plus for positive dash for negative It is also used to show the direction of out of scale range for overload and for underl...

Страница 27: ...r negative If the unit rests at zero the sign will be a plus It is also used to show the direction of out of scale range for overload and for underload Weight These five characters are a string contai...

Страница 28: ...aracters are shown below in tabular form All other status bits are ignored Weight These six characters are a string containing the current gross or net weight not including the decimal point or a sign...

Страница 29: ...played on the remote display These eight characters can include a decimal point and a leading minus to indicate sign E g 300 would represent 300 units 3 00 Is another acceptable string this time with...

Страница 30: ...splay These eight characters can include a decimal point and a leading minus to indicate sign E g 300 would represent 300 units 3 00 Is another acceptable string this time with a decimal point instead...

Страница 31: ...presents the sign of the weight reading space for positive dash for negative Net The numbers to be displayed on the remote display E g 300 would represent 300 units Tare Not used by the remote display...

Страница 32: ...he weight reading space for positive dash for negative Net The numbers to be displayed on the remote display These six characters include a decimal E g 300 0 with leading spaces would represent 300 un...

Страница 33: ...e address is fixed as 1 for this string so the unit must be set to address 1 to display this string Weight The numbers to be displayed on the remote display These four characters can include a decimal...

Страница 34: ...ecifying the address of the unit to display the message The address is fixed as 2 for this string so the unit must be set to address 2 to display this string Text These eight 8 characters will be disp...

Страница 35: ...acter Number 13 14 15 16 17 18 19 20 21 22 23 24 25 Description Byte 12 Byte 13 Byte 14 Byte 15 Byte 16 Byte 17 Byte 18 Byte 19 Byte 20 Byte 21 Byte 22 Byte 23 Byte 24 Character Number 26 27 28 29 30...

Страница 36: ...Number 13 14 15 16 17 18 19 20 21 Description Weight 5 Weight 6 Weight 6 SPC Units 0 Units 1 Units 2 CR LF Function Description Sign Represents the sign of the weight reading for positive dash for neg...

Страница 37: ...escription S1 Weight 0 Weight 1 Weight 2 Weight 3 Weight 4 ESC Ignore Units CR LF Function Description S1 N Net M Net COZ O COZ Units 0 motion 1 grams 2 kilograms Weight The numbers to be displayed on...

Страница 38: ...tion S1 Weight 0 Weight 1 Weight 2 Weight 3 Weight 4 Weight 5 ESC Ignore Units CR LF Function Description S1 N Net M Net COZ O COZ Units 0 motion 1 grams 2 kilograms Weight The numbers to be displayed...

Страница 39: ...e Stable Sign Represents the sign of the weight reading space for positive dash for negative Weight The numbers to be displayed on the remote display The weight value is 5 digits plus an optional deci...

Страница 40: ...Description STX Ignored S1 Ignored SPC SPC Weight 0 Weight 1 Weight 2 Weight 3 ETX Function Description S1 0 Motion 1 COZ 2 Stable SPC Space character ASCII 20H Weight The numbers to be displayed on...

Страница 41: ...ASCII 02H Sign Represents the sign of the weight reading space for positive dash for negative Weight 0 6 These seven characters are a string containing the current weight including the decimal point...

Страница 42: ...Mode Gross GS Net NT Used to actuate the Net annunciator Weight The numbers to be displayed on the remote display These eight characters can include a decimal point and a leading minus to indicate si...

Страница 43: ...table Weight The numbers to be displayed on the remote display These eight characters can include a decimal point and a leading minus to indicate sign E g 300 would represent 300 units 3 00 Is another...

Страница 44: ...turned to the manufacturer for factory service Error Description Resolution E0001 The power supply voltage is too low Check supply E0002 The power supply voltage is too high Check scale cables E0004 C...

Страница 45: ...Remote Display Installation Manual Software Version 4 x D300 602 202 Page 45 Notes...

Страница 46: ...Remote Display Installation Manual Software Version 4 x Page 46 D300 602 202 Notes...

Страница 47: ...Remote Display Installation Manual Software Version 4 x D300 602 202 Page 47 Notes...

Страница 48: ...Remote Display Installation Manual Software Version 4 x Page 48 D300 602 202...

Отзывы: