Remote Display Installation Manual
– Software Version 4.x
Page 34 D300-602-202
5.4.18. Protocol 18: Auto Control String 2
Character
Number
0
1
2
3
4
5
6
7
8
9
10
Description
S
TX
A
d
d
ress
Te
xt
(0)
Te
xt
(1)
Te
xt
(2)
Te
xt
(3)
Te
xt
(4)
Te
xt
(5)
Te
xt
(6)
Te
xt
(7)
E
NQ
Function
Description
STX
Start of Transmission Character (ASCII 02H).
Address
A single character field specifying the address of the unit to
display the message. The address is fixed as 2 for this string
so the unit must be set to address 2 to display this string.
Text
These eight (8) characters will be displayed. They may be
ASCII characters instead of numbers in which case the display
will show text. These eight characters can include a decimal
point and a leading minus to indicate sign. Example:
( 300) would represent 300 units.
( - 3.00) a decimal point and minus sign can be used.
( CEMENT) text can be sent.
ENQ
Used as end of transmission character (ASCII 05H).