RIB2312 Sapphire Gas Log Flame Fire
- 13 -
1/3/18 ©Rinnai
Commissioning the Appliance for different gas type
This appliance is factory set for the correct gas type as per it's gas type labelling, re-commissioning for gas type
will only be required if the PCB is being replaced or if it has undergone a gas type conversion, I.e.; from NG to
Propane or vice versa. Commissioning of the gas is carried out via the PCB.
1. Turn on the gas and power supply to the appliance.
2. With the appliance OFF, press the 'TEST' button
the gas type code will be shown on the display
.
3. Press the 'UP' button
or 'DOWN' button
to obtain the correct gas type code for the appliance. Refer to
the table below for correct gas type code.
4. Press the 'Set' button
to lock in the code.
5. Gas pressure settings should now be checked as per steps 1 and 3 above.
240 VOLTS, RISK OF ELECTRICAL SHOCK! Exercise caution as there is potential for electric
shock from the exposed wiring and circuitry when panels are removed..
DO NOT leave the appliance unattended when the power is connected and the panels are
removed.
Commissioning of the PCB must be carried out BEFORE the gas pressures are checked.
Natural Gas
Propane Gas
A1
L1
WARNING
NOTE
6
14
8
13
11